Chapter 3. Programming Site Data
Transport® Model PT878 Portable Liquid Flowmeter User’s Manual 35
3.3 Entering Pipe Parameters (cont.)
To confirm the entries and return to Operate Mode, press [F3] (OK).
To leave the window without confirming the entries, press [F2] (Cancel)
or the [ESC] key.
In either case, the PT878 returns to Operate Mode.
To return to the Pipe tab and scroll to other windows, press the [S] key.
3.4 Entering Pipe Lining Parameters
To enter the Lining option, scroll to the Lining entry on the Program Menu
and press [ENTER]. (From the Pipe window, you can scroll back up to the
Pipe tab and press the [X] arrow key to reach the Lining window, and press
[ENTER].) The screen appears similar to Figure 18 below. To step through
each parameter, press the [T] key. While programming, refer to Figure144
on page 228 of Appendix A, Menu Maps.
Note: The Lining option is only available for clamp-on transducers.
Figure 18: Pipe Lining Window
Transducer Pipe Path
Transducer/Pipe
Cancel OK
Lining
Material Tar/ Ep ox y
Sound Speed 2000
mm
Thickness
m/s
0
Fluid