Adjustment

Adjustment of the release mechanism

Check that the release bar (30375) is free from the signal arm pawl. Adjust by carefully bending the forward part of the signal arm. Use tool V-2200. Minimum free play: 0.2 mm.

With the camera fully cocked the release bar should protrude a maximum of 0.9 mm through the rear plate. Adjust this by bending the release arm (13357) using tool V-2224.

Fig. 35.

13357

 

min. 0.2 mm

30375

max. 0.9mm

 

Fig. 35

The mirror function should be checked and possibly adjusted before proceeding to adjust the release mechanism.

The mirror should be locked by the mirror catch lever (13356-1). Movement can be increased or reduced by adjusting the mirror actuating lever (13362).

Adjustment is carried out by holding the arm fixed using tool V-2205 and gently bend the forward part of the arm using tool V-2201. Bend downwards for increased mirror movement.

Note! The inner side cover (22813) must be removed before an adjustment can be made.

The mirror’s overtravel should be min. 1 mm. Lubricate the mirror cam (22355) with grease.

Fig. 36.

22335

13362

 

min. 1 mm

13356-1

 

Fig. 36

Revision 0

October 1996

Page 22
Image 22
Hasselblad 10026 service manual Adjustment of the release mechanism