5:1
Camera body 503CW | Adjustment |
The lubricants mentioned in the text are:
Grease = Isoflex Topas L32
Oil = Isoflex PDP 48
Install the winding knob
If the spring is too tight the pressure can be reduced by operation of the shutter mechanism and then pressing the signal arm down.
Fig. 28.
Note! Always check that the auxiliary shutter is closed before turning the winding knob, otherwise there is a risk that the top flap of the shutter will be damaged when the mirror moves downwards.
Temporarily adjust the key position by loosening the screws and moving the bearing bracket (13171) forward until the key position is aligned to the red index dot on the front plate. If the adjustment is insufficient disengage the cogs between the front gear wheel and the gear wheel (13167). Hold the gear by hand during this operation so that the drive spring tension is not lost. Fig. 29.
Loosen the front plate just sufficiently to ensure that the mesh of the teeth is removed and turn the gear one tooth at a time.
Retighten the screws.
20919 |
Fig. 28
Red dot |
Fig. 29
The camera body should now function normally, i.e. shutter release and winding on can be carried out in the normal manner.
Revision 0 | October 1996 |