5:12

Camera body 503CW

Link to: VHABSTS

Adjustment

Calibration and control of the flash metering system TTL

Control/calibration should be carried out each time the camera has been in for repair. The tolerance for the flash meter is ±0.3 EV at all settings.

If the Hasselblad Service System 970600 is used, follow the step by step instruction in the STS user manual.

Note! For calibration work use ISO 100 and LV15. * (ISO 400/LV12).

If the Test box 902474 is used follow the instruction below.

Calibration requires the following test equipment:

-Planar CF80 mm lens with controlled diaphragm values. Deviation max. ±10%.

-Magazine fitted with Kodak´s grey card.

-Stabilized DC power supply adjustable to 7.5 volt ± 0.1 volt.

-Calibrated light box with LV12 and 15.

-Test box 902474.

-Non-conductive trimmer, 2 - 2,5mm.

Set-up for calibration:

 

 

 

Lens

Shutter

B or F

 

 

Aperture

f 5.6

 

Camera body

ISO

100

* (400)

Magazine

Fitted with

 

 

 

grey card

 

 

Test box 902474

Exposure knob

0

* (+1)

 

Tolerance knob

Trim

 

Power supply

Voltage

7.5 ± 0.1v

 

Light box

LV

15

* (12)

 

K-factor

1.3

 

* From camera serial No. from 19ER18271 - See Service info No. 12/98

Revision 1

June 1998

Page 30
Image 30
Hasselblad 10026 service manual Camera body 503CW