Camera body 503CW

The push rod (22369) is adjusted so that it is set 0.15

mmbelow the release bar (30375) forward angle setting. Check by using the tool V-5942.

Adjust by gently bending (22369). Fig. 37.

Position tool V-5942 as shown and press against the front plate. The mechanism should not release.

When the tool is moved upwards the mechanism should release.

If a large adjustment is needed bend the release arm (13357) using tool V-2224. Bend forward for an earlier release and backwards for a delay in release. For a small adjustment the push rod (22369) can be bent.

Fig. 38.

Fig. 39 and 40.

Pre-release the camera shutter by operating the S-arm (21167) towards the angle stop (13432).

Shutter release should occur just as the S-arm strikes the angled stop and at the same time cam ”A” should

be positioned on stop ”B”.

Adjust by bending the S-arm with tool V-2202. Do not forget to re-adjust the angle stop (13432).

Minor adjustments can be carried out by just moving or bending the angle stop (13432) without any adjustments to the S-arm.

Note! That spring 816914 should not rest against the angle stop when the camera is completely released.

Adjustment

 

30375

22369

0.15 mm

Fig. 37

13357

Adjust here

with V-2224

Fig. 38

816914

13432

21167

Fig. 39

"A"

"B"

Fig. 40