Camera body 503CW

Adjustment

Calibration

On pressing the MEASURE button one of the three LED´s will light. The variable resistor in the camera (access behind the leather beside the ISO dial) should be turned so that the green LED lights when the MEASURE button is pressed again.

If the red LED lights, the resistor is turned anticlockwise and if the yellow LED lights, it is turned clockwise. At least two seconds must be allowed between measurements.

Control

To ensure the ISO dial functions, the measurement should also be made for two other ISO settings (50 and 800). * (100 and 1600).

In each case the green LED should light when the MEASURE button is pressed.

ISO

Exposure knob

Tolerance knob

LV

50

+ 1

1/2

15

800

0

1/2

12

100

0

1/2

15

1600

- 1

1/2

12

Variable resistor

* From camera serial No. from 19ER18271 - See Service info No. 12/98

Revision 1

June 1998