Honda Power Equipment TPG-7000H-DXE, TPG-2900H-DX manual G. Using The Generator, H.Ac Application

Models: TPG-4300H-DX TPG-6000H-DX TPG-7000H-DXE TPG-2900H-DX

1 92
Download 92 pages 43.16 Kb
Page 21
Image 21
G. USING THE GENERATOR

Tsurumi’s Operation, Service, and Repair Manual

NOTE:

The choke may not be needed if the engine is warm or the air temperature is high.

(3)Move the throttle lever slightly to the left.

(4)(MODEL TPG-7000H-DXE ONLY): To start the engine using the electric starter, proceed as follows:

(a)Turn key in engine START/STOP switch.

(b)Turn key fully right to START position. Hold in START position until engine starts.

(c)Release key; the key is spring-loaded to the RUN position.

(d)As the engine warms up, gradually move the choke lever to the OPEN position.

(e)Position the throttle lever at the desired engine speed.

(5)(ALL MODELS): When starting the engine using recoil starter, proceed as follows:

(a)Turn the engine switch to the ON position.

(b)Pull the starter grip lightly until resistance is felt, then pull briskly.

NOTE:

When using the recoil starter, do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter.

(c)As the engine warms up, gradually move the choke lever to the OPEN position.

(d)Position the throttle lever at the desired engine speed.

G. USING THE GENERATOR

WARNING:

TO PREVENT ELECTRICAL SHOCK FROM FAULTY APPLIANCES, THE GENERATOR SHOULD BE GROUNDED. CONNECT A LENGTH OF HEAVY WIRE BETWEEN THE GENERA- TOR’S GROUND TERMINAL AND EXTERNAL GROUND SOURCE.

CONNECTIONS FOR STANDBY POWER TO A BUILDING’S ELECTRICAL SYSTEM MUST BE MADE BY A QUALIFIED ELECTRICIAN AND MUST COMPLY WITH ALL APPLICABLE LAWS AND ELECTRICAL CODES. IMPROPER CONNECTIONS CAN ALLOW ELECTRICAL CUR- RENT FROM THE GENERATOR TO BACK-FEED INTO THE UTILITY LINES. SUCH BACK- FEED MAY ELECTROCUTE UTILITY COMPANY WORKERS OR OTHERS WHO CONTACT THE LINES DURING A POWER OUTAGE, AND WHEN UTILITY POWER IS RESTORED, THE GENERATOR MAY EXPLODE, BURN, OR CAUSE FIRES IN THE BUILDING’S ELECTRICAL SYSTEM.

H.AC APPLICATION

ASingle Voltage Type

(1)Check the pilot lamp for proper voltage.

NOTE:

The generator is thoroughly tested and adjusted in the factory. If the generator does not produce the specific voltage, consult your nearest Tsurumi Generator dealer.

(2)Set switches on the electrical appliances to OFF before connecting to the generator.

(3)Insert the plug of the electrical appliance into the appropriate receptacle.

Operating Instructions

Page 18

Page 21
Image 21
Honda Power Equipment TPG-7000H-DXE, TPG-2900H-DX, TPG-6000H-DX, TPG-4300H-DX manual G. Using The Generator, H.Ac Application