NOTE:

Check the amperage of the receptacles used referring to Table 2, and be sure not to take a current exceeding the specified amperage.

Be sure that the total wattage of all appliances does not exceed the rated output of the generator.

WARNING:

TO CONNECT AND LOCK A PLUG IN A TWIST LOCK RECEPTACLE, INSERT THE PLUG INTO RECEPTACLE AND TURN CLOCKWISE.

BE SURE TO GROUND THE GENERATOR IF THE CONNECTED ELECTRICAL EQUIPMENT IS GROUNDED.

NOTE:

When the circuit breaker trips off during operation, the generator is overloaded or the appliance is defective.

When the circuit breaker trips, stop the generator immediately. Check the appliance and/or gener- ator for an overload or defect and repair as necessary.

CAUTION:

The 120V duplex receptacle is protected by a GFCI (Ground Fault Circuit Interrupter). The GFCI shuts off the output current from the 120V duplex receptacle when a ground fault occurs in the generator or the appliance.

Please note that other receptacles are not protected by a GFCI.

BDual Voltage Type

(1)Select the voltage using the FULL POWER switch in accordance with the electrical appli- ance. Refer to Table 3.

(2)Operate the generator in the same way as step (a) through step (c) of single voltage type.