Table 3

Tsurumi’s Operation, Service, and Repair Manual

Table 3

Available Receptacles With Full Power Switch On

Switch Setting

Lower Voltage Receptacle

Higher Voltage Receptacle

 

 

 

 

 

120V

Rated Output is Available

Unavailable

 

 

 

 

 

120V/240V

Half of Rate Output is Available

Rated Output is Available

 

 

 

 

 

WARNING:

TO TAKE OUT POWER FROM TWIST LOCK RECEPTACLE, INSERT THE PLUG INTO RECEP- TACLE AND TURN CLOCKWISE TO LOCK IT.

BE SURE TO GROUND THE GENERATOR IF THE CONNECTED ELECTRICAL EQUIPMENT IS GROUNDED.

NOTE:

When the circuit breaker turns off during operation, the generator is overloaded or the appliance is defective.

Stop the generator immediately, check the appliance and/or generator for overloading or defect and repair as necessary.

I.STOPPING THE GENERATOR

(1)Set the power switch to OFF or unplug the cord from the receptacle.

(2)Move the throttle lever fully to the right.

(3)Turn the engine switch to the OFF position.

(4)Turn the fuel valve to the OFF position.

Figure 15: Fuel Valve

Operating Instructions

Page 20

Page 23
Image 23