Setting

Serial

 

Selection

Command

Page

* Indicates default

# Indicates a

 

 

 

 

numeric entry

 

 

 

 

 

 

 

 

 

Beeper Duration - Good Read

*Normal Beep

BEPBIP0

3-2

 

 

 

 

 

Short Beep

BEPBIP1

3-2

 

 

 

 

LED - Good Read

Off

BEPLED0

3-2

 

 

 

 

 

*On

BEPLED1

3-2

 

 

 

 

LED - Indicator State

*Off

BEPPOI0

3-2

 

 

 

 

 

On

BEPPOI1

3-2

 

 

 

 

Number of Beeps - Good Read

*1

BEPRPT1

3-2

 

 

 

 

 

Range 1 - 9

BEPRPT#

3-2

 

 

 

 

Good Read Delay

*No Delay

DLYGRD0

3-3

 

 

 

 

 

Short Delay (500 ms)

DLYGRD500

3-3

 

 

 

 

 

Medium Delay (1000 ms)

DLYGRD1000

3-3

 

 

 

 

 

Long Delay (1500 ms)

DLYGRD1500

3-3

 

 

 

 

User-Specified Good Read Delay

Range 0 - 30,000 ms

DLYGRD#####

3-3

 

 

 

 

Manual/Serial Trigger

*Manual/Serial Trigger Mode

TRGMOD0

3-3

 

 

 

 

 

Read Time-Out

TRGSTO####

3-4

 

(0 - 300,000 ms) *30,000

 

 

 

 

 

 

 

 

Scan Stand

Scan Stand Mode

TRGMOD4

3-4

 

 

 

 

 

Scan Stand Symbol

FNC3

3-4

 

 

 

 

Presentation

Presentation Mode

TRGMOD3

3-4

 

 

 

 

Presentation Sensitivity

Range 0-20 (*1)

TRGPMS##

3-5

 

 

 

 

Hands Free Time-Out

Range 0 - 300,000 ms

TRG-

3-5

 

 

PTO######

 

 

 

 

 

Reread Delay

Short (500 ms)

DLYRRD500

3-5

 

 

 

 

 

*Medium (750 ms)

DLYRR750

3-5

 

 

 

 

 

Long (1000 ms)

DLYRRD1000

3-5

 

 

 

 

 

Extra Long (2000 ms)

DLYRRD2000

3-5

 

 

 

 

User-Specified Reread Delay

Range 0 - 30,000 ms

DLYRRD#####

3-6

 

 

 

 

LED Power Level

Off

PWRLDC0

3-6

 

 

 

 

 

Low (50%)

PWRLDC50

3-6

 

 

 

 

 

*High (100%)

PWRLDC100

3-6

 

 

 

 

Imager Time-Out

Range 0 - 999,999 ms

SDRTIM#####

3-6

 

(*60,000 ms)

#

 

 

 

 

 

Aimer Delay

200 milliseconds

SCNDLY200

3-7

 

 

 

 

 

400 milliseconds

SCNDLY400

3-7

 

 

 

 

 

*Off (no delay)

SCNDLY0

3-7

 

 

 

 

User-Specified Aimer Delay

Range 0 - 4,000 ms

SCNDLY####

3-7

 

 

 

 

Aimer Mode

Off

SCNAIM0

3-7

 

 

 

 

 

Interlaced

SCNAIM2

3-7

 

 

 

 

10 - 6