User-Specified Reread Delay

If you want to set your own length for the reread delay, scan the barcode below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save.

User-Specified Reread Delay

LED Power Level

This selection allows you to adjust LED and aimer brightness. Off is used when no illumination is needed. Low is used if low illumination is sufficient. High (the default) is the brightest setting.

If you have an aimer delay programmed (see Aimer Delay on page 3-7),the aimer will be at 100% power during the delay, regardless of the LED Power Level. Default = High.

Note: If you scan the Off barcode, both the aimer and illumination lights turn off, making it impossible to scan barcodes in low light. To turn the LED Power Level back on, move to a brightly lit area and scan either the Low or the High barcode below.

Off

Low (50%)

*High (100%)

Imager Time-Out

Imager Time-Out powers down the document reader after the unit has been idle for the specified time. To prevent the document reader from powering down, set this time-out to 0. Scan the barcode below, then set the time-out by scanning digits (from 0 - 999,999 ms) from the inside back cover, then scanning Save. Default = 60,000 ms.

Imager Time-Out

3 - 6

Page 26
Image 26
Honeywell 4800dr manual User-Specified Reread Delay, LED Power Level, Imager Time-Out