43

start character match for Code 93, 43h = “C”

FF

termination string for third code

Output Sequence Editor

Enter Sequence

Default Sequence

Require Output Sequence

When an output sequence is Required, all output data must conform to an edited sequence or the doc- ument reader will not transmit the output data to the host device. When it’s On/Not Required, the docu- ment reader will attempt to get the output data to conform to an edited sequence, but if it cannot, the document reader transmits all output data to the host device as is.

When the output sequence is Off, the barcode data is output to the host as the document reader decodes it. Default = Off.

Note: This selection is unavailable when the Multiple Symbols Selection is turned on.

Required

On/Not Required

*Off

Multiple Symbols

When this programming selection is turned On, it allows you to read multiple symbols with a single pull of the Document Reader’s trigger. If you press and hold the trigger, aiming the Document Reader at a series of symbols, it reads unique symbols once, beeping (if turned on) for each read. The document reader attempts to find and decode new symbols as long as the trigger is pulled. When this program- ming selection is turned Off, the Document Reader will only read the symbol closest to the aiming beam. Default = Off.

On

* Off