5.Finally, set up the ISBN check digit, which is a special position-weighted modulo 11 checksum. The imager automatically invokes the ISBN checksum for template rows that are:

1.) at least fourteen characters long,

2.) whose first four characters are the letters “ISBN,”

3.) whose last character is a check character, and

4.) when the modulo 11 check character “0123456789X” is programmed.

Please note that all these commands can be combined into a single serial programming command:

OCRENA2,TMP”ISBNggggggggggggctCdddd hdddEtCdddd hddddE”,GPG”0123456789-”,GPH”P\”,CHK”0123456789X”.

These commands can be encoded into the following Aztec Code symbol:

OCR Template Codes

Note: Reading more than three rows of OCR is not recommended. Contact the factory if you have an application that requires reading four or more rows of OCR.

Enter OCR Template

Enter User-Defined

Variable “g”

Enter User-Defined

Variable “h”

One or more two-digit numbers and Save are required after reading this programming symbol. Refer to the Programming Chart on the inside the back cover of this manual.

Exit Selections

Save OCR Template

Discard OCR Template

7 - 10