Function Code Transmit

When this selection is enabled and function codes are contained within the scanned data, the document reader transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys starting on page 8-2. When the document reader is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted. Default = Enable.

* Enable

Disable

Intercharacter, Interfunction, and Intermessage Delays

Some terminals drop information (characters) if data comes through too quickly. Intercharacter, inter- function, and intermessage delays slow the transmission of data, increasing data integrity.

Each delay is composed of a 5 millisecond step. You can program up to 99 steps (of 5 ms each) for a range of 0-495 ms.

Intercharacter Delay

An intercharacter delay of up to 495 milliseconds (in 5 ms steps) may be placed between the transmis- sion of each character of scanned data. Scan the Intercharacter Delay barcode below, then scan the number of 5 millisecond steps (0-99), and the Save barcode using the Programming Chart inside the back cover of this manual.

Prefix

Scanned Data

Suffix

1 2 3 4

Intercharacter Delay

5

Intercharacter Delay

To remove this delay, scan the Intercharacter Delay barcode, then set the number of steps to 0. Scan the Save barcode using the Programming Chart inside the back cover of this manual.

Note: Intercharacter delays are not supported in USB serial emulation.

User Specified Intercharacter Delay

An intercharacter delay of up to 495 milliseconds (in 5 ms steps) may be placed after the transmission of a particular character of scanned data. Scan the Delay Length barcode below, then scan the number of 5 millisecond steps (0-99), and the Save barcode using the Programming Chart inside the back cover of this manual.

4 - 4

Page 40