EAN•UCC Composite Code Message Length

Scan the barcodes below to change the message length. Refer to Message Length Description (page 6-

2)for additional information. Minimum and Maximum lengths = 1-2435. Minimum Default = 1, Maximum Default = 2435.

Minimum Message Length

Maximum Message Length

EANUCC Emulation

The document reader can automatically format the output from any EAN•UCC data carrier to emulate what would be encoded in an equivalent UCC/EAN-128 or GS1 DataBar and Composite symbol. EAN•UCC data carriers include UPC-A and UPC-E, EAN-13 and EAN-8, ITF-14, UCC/EAN-128, and EAN•UCC GS1 DataBar and Composites. Data from 2D symbols such as Aztec Code, Data Matrix, or QR Code, which encode a leading FNC1, also invoke EAN•UCC emulation. If 128 Emulation is selected, the AIM Symbology Identifier is reported as “]C1”. If GS1 DataBar Emulation is selected, the AIM Symbology Identifier is reported as “]e0.” Any application that accepts EAN•UCC data can be sim- plified since it only needs to recognize one data carrier type. Default = EAN•UCC Emulation Off.

GS1 DataBar Emulation

128 Emulation

* EAN•UCC Emulation Off

TCIF Linked Code 39 (TLC39)

This code is a composite code since it has a Code 39 linear component and a MicroPDF417 stacked code component. All barcode readers are capable of reading the Code 39 linear component. The MicroPDF417 component can only be decoded if TLC39 On is selected. The linear component may be decoded as Code 39 even if TLC39 is Off. Default = Off.

On

* Off

Postal Codes

Note: For best performance when reading a postal symbology, all other postal symbologies should be turned off.

6 - 31

Page 79
Image 79