Menu is busy

The system MENU is already being used by another operator.

 

 

 

 

Wait a while and try again.

 

 

 

 

 

 

 

 

Test mode frozen

The diagnostic test mode display has been frozen. The system

 

 

 

 

MENU cannot be used until the diagnostic test mode is released.

 

 

 

 

Wait for the service engineer to complete their testing, then try to

 

 

 

 

access the system MENU again.

 

 

 

 

 

 

 

 

LIC:XX_DAYS_LEFT

This prompt indicates that you are running a trial version of the

 

 

 

 

software.

 

 

 

 

This text is prompted in the message line, if the remaining trial

 

 

 

 

period is greater than 5 days. If the trial period is less than or equal

 

 

 

 

to 5 days, then the message is shown in the mode line and the

 

 

 

 

message is displayed on every monitor once after every thirty

 

 

 

 

selections.

 

 

 

 

 

 

 

 

LIC:EXPIRED

This message is displayed on all monitors when the trial period of

 

 

 

 

software expires. This is displayed on the mode line of every

 

 

 

 

monitor. No switching is allowed once the license expires and

 

 

 

 

every issue of the switching command results in a display of this

 

 

 

 

message.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8.9

ERRORS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Message Prompt

Explanation

 

 

 

 

 

 

 

 

 

 

 

 

 

?? Fault errorlog

The ERRORLOG.MAX report file on the storage disk is full. You

 

 

 

 

should contact technical support as soon as possible to have the

 

 

 

 

report file analyzed. Once the reported problems have been dealt

 

 

 

 

with, the service engineer should delete the report file and re-boot

 

 

 

 

the system.

 

 

 

 

 

 

 

 

Runtime error #..

The system has ceased operation completely. Record the Runtime

 

 

 

 

error number and call technical support for immediate support.

 

 

 

 

Try re-booting the MAXPRO-Net Server to re-establish normal

 

 

 

 

system operation.

 

 

 

 

 

 

 

 

?? Macro error #..

The internal macro environment in your system has reported an

 

 

 

 

incomplete macro event. The macro error number can be used to

 

 

 

 

identify the event problem. Keep written log records of the macro

 

 

 

 

error number together with the system event causing the macro

 

 

 

 

error and the time/date it occurred. Macro errors can occur in a

 

 

 

 

fully functioning system but should be attended to during normal

 

 

 

 

system maintenance.

 

 

 

 

 

 

 

 

Subrack Fail (xxx)

The equipment subrack (xxx) in the hardware has failed to respond

 

 

 

 

to polling commands. The data communication channel to the

 

 

 

 

subrack may be disconnected or the subrack controller module

 

 

 

 

may have failed. Call technical support for immediate support.

 

 

 

 

 

 

 

 

HL Fail (xxx)

The external computer system (xxx) connected to the system has

 

 

 

 

failed to respond to polling commands. The data communication

 

 

 

 

channel to this equipment may have failed. Call technical support

 

 

 

 

for immediate support.

 

 

 

 

 

 