Option | Action |
|
|
Aim Time | Duration of the imager aim beam in 0.1 second increments. |
| Valid:0 – 50 (0 to 5 seconds) |
| Default:0 |
|
|
Lights | Specifies if the imager's lights and aimer should be left on during the entire decode process. |
| The default is disabled. |
| If disabled, the lights are turned on only during image capture, then turned off while the imager |
| attempts to process and decode the bar code. |
| If enabled, the aimer and lights remain turned on during the entire process. |
| In Aggressive Linear Decode mode, set this parameter to enabled to improve the aimer visibility. |
| See “Mode” above. |
|
|