Basic Troubleshooting
Verifying PRLI Data
The router returns the PRLI (preliminary login) response data as specified in Table 12.
In the default configuration, the router returns PRLI Data (PRLI Accept Payload) with the Target bit SET and the Initiator bit CLEAR. However, some configurations require the Initiator bit be SET, such as in
Table 12: PRLI |
|
|
|
Item | Value |
PRLI Command Code | 0x20 |
|
|
Page Length | 0x10 |
|
|
Payload Length | 0x10 |
|
|
Type Code | 0x8 |
|
|
Type Code Extension | 0x0 |
|
|
OPA | 0x0 |
|
|
RPA | 0x0 |
|
|
IPE | 0x1 |
|
|
Response Code | 0x1 |
|
|
Originator Process Associator | 0x0 |
|
|
Responder Process Associator | 0x0 |
|
|
Initiator Function | 0x1 |
|
|
Target Function | 0x1 |
|
|
Command/Data Mixed Allowed | 0x0 |
|
|
Data/Response Mixed Allowed | 0x0 |
|
|
Read XFER_RDY Disabled | 0x1 |
|
|
Write XFER_RDY Disabled | 0x0 |
|
|
Network Storage Router | 159 |