Visual Manager User Interface
Caution: If this configuration setting is incorrectly set, processing difficulties may occur. Before changing this setting, evaluate the need for the change and verify the desired setting. HP recommends backing up the router configuration to an external file before making changes to this setting.
Note: Target IDs must be setup before mapping devices on the SCSI bus.
Note: Do not enable Target IDs unless there is a SCSI initiator on the bus that wants to use Fibre Channel devices. This type of configuration is known as a Target Mode configuration.
■Discovery toggles between Enabled and Disabled.
■Discovery Delay is the wait time after a
Note: HP recommends setting the value to at least 30 seconds to ensure all SCSI devices complete their individual
■Bus Reset on Boot toggles between Enabled and Disabled.
When enabled, the router will automatically reset SCSI buses during a power up or reboot of the router.
■Internal Termination toggles between Enabled and Disabled.
Caution: If this configuration setting is incorrectly set, processing difficulties may occur. Before changing this setting, evaluate the need for the change and verify the desired setting. HP recommends backing up the router configuration to an external file before making changes to this setting.
When enabled, internal termination of the selected SCSI bus is allowed. When disabled, the SCSI Bus, not the router handles SCSI termination.
■Buffered Tape Writes (default: Enabled) toggles between Enabled and Disabled.
Network Storage Router | 61 |