HP Microsoft Windows Server 2003 for Itanium-based Systems manual Script file options

Models: Microsoft Windows Server 2003 for Itanium-based Systems

1 70
Download 70 pages 19.35 Kb
Page 33
Image 33

*LogicalDriveSSPState = EnableDisable

*SSPAdaptersWithAccess = [N],[N]...None

HBA_WW_ID = WWN

ConnectionName = UserDefinedName

HostMode = DefaultWindowsWindows(degrade)openVMSTru64Linux SolarisNetwareHPWindows Sp2

Script file options

There are four categories of options in ACU script files: Control, Controller, Array, and Logical Drive. Each category has several scripting options, but you do not always need to assign values to every option. ACU can use default values in some cases, while in other cases, a given option might not be relevant for a particular controller or operating mode.

The options for each category are listed in the table ("Description of option categories in ACU scripting" on page 33), and described in more detail in the rest of this section.

Description of option categories in ACU scripting

Category

Options

Comments

 

 

 

Control

Action

These options define the overall behavior of ACU

 

Method

when it processes the scripts and creates

 

configurations. Control options can occur only once in

 

 

 

 

a script file, and must be the first options listed.

 

 

 

Controller

Controller

Options in this category define the controller that is to

 

ClearConfigurationWithDataLoss

be configured (or the controller that has had its

 

configuration captured). The Controller option must be

 

LicenseKey

 

at the beginning of this section of the script, but you

 

DeleteLicenseKey

can script other options in this category in any order.

 

RAIDArrayID

You can use one script to configure several controllers

 

ReadCache

if all controllers are to be configured identically, or if

 

you define each controller configuration separately.

 

WriteCache

 

When you define each controller separately, specify

 

RebuildPriority

all category options for a particular controller before

 

ExpandPriority

starting a new controller listing.

 

 

 

SurfaceScanDelay

 

 

SSPState

 

 

 

 

Array

Array

These options define an array that is to be configured

 

OnlineSpare

on the controller that is identified previously in the

 

script. (If no controller is previously identified, ACU

 

Drive

 

sends an error message.) The Array option must be at

 

 

the beginning of this section of the script, but you can

 

 

script the other options in this category in any order.

 

 

 

Scripting in ACU 33

Page 33
Image 33
HP Microsoft Windows Server 2003 for Itanium-based Systems manual Script file options