HP Microsoft Windows Server 2003 for Itanium-based Systems manual ACU scripting error messages

Models: Microsoft Windows Server 2003 for Itanium-based Systems

1 70
Download 70 pages 19.35 Kb
Page 40
Image 40

ACU scripting error messages

Message

Comment or explanation (if not self-explanatory)

 

 

(text) is not a controller command

--

 

 

(text) is not a logical drive

--

command

 

 

 

(text) is not a supported command

--

 

 

(text) is not an array command

--

 

 

(text) command expected

The specified command is missing or in the incorrect place in the

 

file.

 

 

Array not specified

Some commands in the script require an array, but no array is

 

specified in the script file.

Array requires an odd number of

This error message occurs if you attempt to add an odd number of

drives

drives to an existing array that has RAID 1 logical drives, and the

 

controller does not support RAID-level migration.

 

 

Cannot change array spare

The current configuration does not allow the number of spares in the

 

array to be changed.

Cannot change logical drive array

The current controller configuration does not allow the array

accelerator setting

accelerator setting to be changed.

 

 

Cannot change logical drive

You cannot change the MaxBoot setting on a configured logical

sectors

drive because doing so causes data loss.

 

 

Cannot change SSP settings

--

 

 

Cannot create array

The controller either has no unassigned physical drives, or it already

 

has the maximum number of arrays or logical drives.

Cannot create logical drive

There is no free space on the array, or the maximum number of

 

logical drives has already been reached.

 

 

Cannot expand array

The controller does not support expansion, or the current

 

configuration of the controller does not allow expansion.

 

 

Cannot extend logical drive

The controller does not support extension, or the current

 

configuration does not allow extension. For example, if there is no

 

free space on an array, extension is not supported.

 

 

Cannot migrate logical drive RAID

The controller does not support RAID migration, or the current

 

configuration of the controller does not allow migration.

 

 

Cannot migrate logical drive stripe

The controller does not support stripe size migration, or the current

size

configuration of the controller does not allow migration.

Cannot remove physical drives

You have inadvertently omitted one or more physical drives from the

from existing array

drive list when reconfiguring an existing array. ACU does not allow

 

this because removing physical drives from a configured array

 

causes data loss.

Controller (text) is invalid

The controller specifications are not entered correctly.

 

 

Controller does not support

--

controller SSPState. Use the

 

LogicalDriveSSPState command to

 

set SSP states for each logical

 

drive.

 

 

 

Controller does not support license

--

keys

 

 

 

Scripting in ACU 40

Page 40
Image 40
HP Microsoft Windows Server 2003 for Itanium-based Systems manual ACU scripting error messages