HP Microsoft Windows Server 2003 for Itanium-based Systems manual Overview for using ACU

Models: Microsoft Windows Server 2003 for Itanium-based Systems

1 70
Download 70 pages 19.35 Kb
Page 6
Image 6

Setting the execution mode for Microsoft Windows

During the installation process on a server using a supported Microsoft® Windows® operating system, you are prompted to select the Execution Mode setting. This setting determines whether you can run ACU on the server from a remote network location.

You can change the execution mode at any time by selecting Setup HP Array Configuration Utility from the Start menu.

Comparison of ACU execution modes

Local Application mode

Remote Service mode

 

 

ACU is installed as an executable

ACU is installed as a service that

application.

starts when the server is powered up.

 

 

ACU runs only on the local system

ACU can be run remotely from

and cannot be run remotely.

another server across a network.

A browser is used to render the user

 

interface, but no Web server is

 

required.

 

 

 

Authentication is handled by the

Authentication is handled through the

operating system, ensuring that the

same mechanism used for Systems

user is an administrator on the server

Insight Manager agents.

running ACU.

 

 

 

Overview for using ACU

1.Open ACU.

You can operate ACU in scripting mode ("Scripting in ACU" on page 31), CLI mode ("Using the Command Line Interface" on page 43), or GUI mode. Furthermore, you can access the GUI mode in the following ways:

As a local application (this method is available only on Microsoft® Windows® platforms) ("Opening ACU in Local Application mode" on page 7)

Through a browser ("Opening ACU in Browser mode" on page 8)

Through HP Systems Insight Manager ("Opening ACU through Systems Insight Manager" on page 9)

Getting started 6

Page 6
Image 6
HP Microsoft Windows Server 2003 for Itanium-based Systems manual Overview for using ACU, Comparison of ACU execution modes