HP Microsoft Windows Server 2003 for Itanium-based Systems manual

Models: Microsoft Windows Server 2003 for Itanium-based Systems

1 70
Download 70 pages 19.35 Kb
Page 41
Image 41

Message

Comment or explanation (if not self-explanatory)

 

 

 

 

Controller does not support logical

--

 

drive SSP states. Use the SSPState

 

 

command to set the controller SSP

 

 

state.

 

 

 

 

 

Controller does not support

The controller is not redundant or does not support redundancy

 

redundancy settings

settings.

 

Controller does not support

--

 

RAIDArrayID

 

 

 

 

 

Controller does not support SSP

--

 

 

 

 

Controller has maximum number

--

 

of license keys

 

 

 

 

 

Controller is locked by another

--

 

machine or user

 

 

Controller requires non-failed

--

 

physical drives to set license keys

 

 

 

 

 

Controller requires physical drives

--

 

to set license keys

 

 

 

 

 

Could not detect controller (text)

--

 

 

 

 

Error communicating with

--

 

controller

 

 

Error saving controller

There is a problem saving one or more controller configurations.

 

 

 

 

Failure opening capture file (text)

--

 

 

 

 

Failure opening input file (text)

--

 

 

 

 

Internal error

An internal ACU error has occurred, and some error is not being

 

 

identified properly.

 

 

 

 

Invalid array accelerator setting

The specified array accelerator setting is invalid or is not supported

 

 

with the current configuration.

 

 

 

 

Invalid array

The array ID is invalid.

 

 

 

 

Invalid

--

 

ClearConfigurationWithDataLoss

 

 

parameter

 

 

 

 

 

Invalid Controller

--

 

 

 

 

Invalid expand priority

The specified expand priority is not supported, or the controller does

 

 

not allow expansion and therefore does not support the Expand

 

 

Priority feature.

 

Invalid license key

--

 

 

 

 

Invalid logical drive

The logical drive ID is not valid.

 

 

 

 

Invalid Method

Invalid Method value.

 

 

 

 

Invalid physical drive

The physical drive listed for the array is not a valid physical drive,

 

 

or it is a physical drive that is not capable of being placed in the

 

 

array.

 

 

 

 

Invalid RAIDArrayID

The entered RAIDArrayID is invalid. Use characters from the set a–z,

 

 

A–Z, 0–9, !, @, #, *, (, ), ,, -, _, +, :, ., /, and [space]. The ID

 

 

cannot end with a space character or exceed the maximum number

 

 

of characters allowed by the controller.

 

 

 

 

Invalid RAID

The specified RAID level is invalid or is not possible with the current

 

 

configuration.

 

 

Scripting in ACU 41

Page 41
Image 41
HP Microsoft Windows Server 2003 for Itanium-based Systems manual 0-9, !, @, #, *, , , ,, -, , +, , ., /, and space. The ID