WARNING! The curing module terminal block must use the same configuration as the drying module.

Check resistances

Check the resistance at the output of the static relay, as shown below, through the hole protecting the static relay.

Also check the resistance between A2-B2, A2-C2, B2-C2 (marked on the static relay and on the heating and curing cables: 1, 2, 3).

The acceptable values are as follows.

Triangle configuration (low input tri-phase, 200-220 V between phases): resistance should be

16 Ω (minimum: 15 Ω , maximum: 17 Ω).

Star configuration (high input tri-phase, 380-415 V between phases): resistance should be 32 Ω

(minimum: 30 Ω, maximum: 34 Ω).

Check connections

Check that the following items are correctly connected.

The main interconnect

The left remote controller board (remove the left trim)

The ink supply module board

The capping station's remote controller board

The printhead cleaning roll station

The tri-phase cables on the static relay: within the electrical cabinet, on the left, the two big black relays)

The neutral or zero line of the tri-phase cables must not be connected.

ENWW

Check resistances 31