Choose delta or star (Y) configuration

Manpower

Tools

Time

 

 

 

1 person

T10 and M15 screwdriver, M7 wrench

5 minutes

 

 

 

There are two Delta/Star terminal blocks located on the printer that must be configured. Use the following table to make the configuration, and follow the procedures below to access the two terminal blocks.

CAUTION: Both Delta/Star terminal blocks must use the same configuration.

Delta configuration1

Star configuration2

 

 

1Use the delta configuration for tri-phase power supply voltages from 200–220 V (between phases).

2Use the star configuration for tri-phase power supply voltages from 380–415 V (between phases).

Heating Module Configuration

1.Remove the six T10 screws securing the middle cover of the heating module and remove it.

TIP: The heating module cover you must remove is marked with orange tape.

ENWW

Choose delta or star (Y) configuration 29