45
MEASURE-Peak Capability Results Torque
----------------------------------- ---------------------------
No of Samples 200 Based on last 15. samples
Transducer C I/S 75.00 Nm /x 6.96 Nm
Serial Number: 99999 Range 8.30 Nm
Measurement Dir Right Sigma 2.210
Max Torque Value 20.00 Nm Cp 0.754
Min Torque Value 10.00 Nm Cpk - 0.458
Thrshld Torq Val 2.00 Nm Max found 12.65 Nm
Freq response 1676 Hz Min found 4.35 Nm
Cycle end time 0.1 Sec Readings above max 0.
Readings below min 13.
Percentage not OK 86.66 %
Date Time Torque
1 07/01/95 12:38:32 7.21 LO
2 07/01/95 12:38:35 4.87 LO
3 07/01/95 12:38:38 6.65 LO
4 07/01/95 12:38:40 6.56 LO
5 07/01/95 12:38:42 7.45 LO
6 07/01/95 12:38:45 5.76 LO
7 07/01/95 12:38:47 7.07 LO
8 07/01/95 12:38:49 12.65
9 07/01/95 12:38:52 9.37 LO
10 07/01/95 12:38:54 5.29 LO
11 07/01/95 12:38:56 6.09 LO
12 07/01/95 12:38:59 4.35 LO
13 07/01/95 12:39:01 5.90 LO
14 07/01/95 12:39:04 5.25 LO
15 07/01/95 12:39:06 10.03

Example Printout of Readings taken in Measure Mode

7529_eng.fm Page 45 Wednesday, November 12, 2003 8:57 AM