7529_eng.fm Page 58 Wednesday, November 12, 2003 8:57 AM

 

 

Error Messages

Code

Message

Explanation

101

RANGE

The selection made is not within the allowable

 

 

range. See the limits specified max to min.

104

EXISTS

The characteristic name entered already exists.

105

NO SPACE

Insufficient memory space is available to create a

 

 

new characteristic.

106

NONE

No characteristics have been created.

107

ON PC

Characteristic or round was sent from PC. These

 

 

may not be edited or erased on ETA.

108

CONV’ OUT

The units selected would generate too great or

 

OF RANGE

too small a number.

109

NO NAME

A characteristic name must be entered.

110

NO SETUP

The characteristic exists but configuration is not

 

 

complete.

111

NO DATA

The characteristic exists, but no data is stored.

113

DAT STR

More than one sub group of data is now stored.

114

ALL STR

All of the sub groups for this characteristic have

 

 

now been collected. Erase these after printing to

 

 

allow further collection.

120

NO Tx

Transducer has been selected but none is

 

 

connected.

121

TxID - FLT

Transducer ID level not recognized. Use another

 

 

transducer or get transducer recalibrated.

122

AZ OFSET

An auto-zero calibration on the transducer has

 

 

detected an excessive offset from zero.

58