Direct Measure Mode - ETA5 ONLY

(Ingersoll-Rand TRD, TSD or

Crane UTA Type Transducers)

Direct measure mode allows an operator to connect different transducers which may have differ- ent spans and an angle output, and can switch between them using an external T switch. This is a display only function and readings are not stored or printed out.

To start, press

ON

 

 

press

MENU

 

 

press

4

(Direct)

 

press

1

(Direct Measure)

press

1

(Setup)

 

select units of measure using

 

; press

Enter

select peak, track, Impulse or ‘Click Dip’ using

; press Enter

select measurement direction using (Right is clockwise. Left is anti-clockwise);

press Enter

select ‘Cycle end Time’ using

; press

Enter

 

select frequency response using

; press

Enter

 

type in the Threshold Percent (mx 50.0; mn 0.0), and press

Enter

type in amount of Click (mx 100.0 Nm; mn 0.0 Nm), and press

Enter

select ‘Second Parameter’ using

; press

Enter

 

Screen shows “End of Setup”, press

MENU to exit

 

 

press MENU MENU to return to main menu