A p p e n d i x

A Technical Information

Electrical Specifications

AC line frequency: 47Hz-63Hz

Fuse: 100-120V/4A 200-240V/2A

Power Cord Specifications

115 volt configuration:

Minimum type SJT (SVT) 18/3, rated 250 Volts AC, 10 Amps with a maximum length of 15 feet. One end is terminated in an IEC 320 attachment plug, the other in a NEMA 5-15P plug.

230 volt configuration:

Minimum type SJT (SVT) 18/3, rated 250 Volts AC, 10 Amps with a maximum length of 15 feet. One end is terminated in an IEC 320 attachment plug. The other end is terminated as required by the country where it will be installed.

Electromagnetic Emissions and Safety Agency Approval

FCC Part 15, Subpart J, Class A

EN 55022 (CISPR22: 1985), Class A VCCI Class 1 ITE

EN50082-1

UL listed (UL 1950) third edition

TUV certified to IEC 950 second edition plus A1/A2 and EN60950 A1/A2

CE Mark

CSA certified (CSA 22.2 #950) Electrostatic discharge (ESD): IEC 801-2 Radiated Electromagnetic field: IEC 801-3 Electrical Fast Transient/burst: IEC 801-4

Environment

Operating temperature: 0 ~ 40° C (32 ~ 104° F)

Storage temperature: -10 ~ 65° C (14 ~ 149° F)

Humidity: < 85% (noncondensing)

ETL (UL-1950), TUV/VDE, CSA