Installing and Replacing Mobile Board Components

Attaching the Touch Pad and the Fingerprint Reader (optional) Cables

This section describes how to connect the touch pad and fingerprint reader cables to the Mobile Board after it has been installed in the chassis. To connect the cables, see Figure 17 and follow these steps:

1.Observe the precautions in "Before You Begin" on page 35.

2.Turn the chassis over so that it is oriented (top side up) as shown in Figure 17.

3.If the touch pad installed in the C-tray includes an optional fingerprint reader, there will be two cables to connect. The touch pad cable attaches to the touch pad connector (Figure 1, H) and the fingerprint reader cable attaches to ID Expansion Connector B (Figure 1, G). The installation process is the same for both cables.

4.To connect either of the cables:

a.Open the connector locking mechanism (Figure 17, A) by sliding it out as shown in the figure.

b.Insert the cable into the connector (Figure 17, B).

c.Push the locking mechanism (Figure 17, A) back in to lock the cable in place.