Raptor AT – Installation Guide
Clock Speed Selection
The Raptor AT has a CPU automatic speed selector device. The jumper JP11 allows selection for this option.
Table
Clock | JP11 | JP11 | JP11 |
Frequency | |||
AUTODETECT* | Closed | Open | Open |
66MHz | Open | Closed | Open |
100MHz | Open | Open | Closed |
* Manufacturer's Settings.
Watchdog Timer Selection
The watchdog timer can be set as hardware, software or disabled through JP10. JP8 sets the
Table
Watchdog | JP10 | JP10 | JP10 |
Type | |||
Hardware | Closed | Open | Open |
Disabled* | Open | Closed | Open |
Software | Open | Open | Closed |
* Manufacturer's Settings. |
|
| |
Table |
| ||
|
|
|
|
Watchdog | JP8 | JP8 | JP8 |
Timeout | |||
1200 ms* | Closed | Open | Open |
600 ms | Open | Closed | Open |
150 ms | Open | Open | Closed |
* Manufacturer's Settings.
6