Table 3. SW4 Light Path Diagnostics LED locations

LED error

Action

 

 

NMI

Ceck the error log for additional information. Reboot the blade

 

server. If the error still exists, replace the system board.

 

 

MIS

Check the processors to make sure they are at the same

 

speed.

 

 

SBRD

Reboot the blade server. If the error still exists, replace the

 

system board.

 

 

TEMP

Check the SBCE unit blowers and air inlets. Check the room

 

temperature.

 

 

Light Path Diagnostics LED

Check the Light Path Diagnostics LED for errors

 

 

Ligh Path Diagnostics button (SW4)

Press SW4 to locate faults on the system board. If the

 

processor or memory LED is lit, reseat the component. If the

 

LED remains lit, replace the defective component.

 

 

See “Diagnosing problems using Light Path Diagnostics” on page 65 for information on what action to take if there is a component error.

18

Intel Server Compute Blade SBX82 Installation and User’s Guide