Intel SBX82 manual Light path diagnostics

Models: SBX82

1 88
Download 88 pages 16.07 Kb
Page 81
Image 81

Table 7. Light path diagnostics

LED

Problem

Action

 

 

 

None

An error has occurred and cannot

Check the system error log in the management

 

be isolated, or the service processor

module for more information about the error.

 

has failed. The error is not

 

 

represented by a light path

 

 

diagnostic LED.

 

 

 

 

DIMM x error

A memory error has occurred.

Replace the failing DIMM, indicated by the lit DIMM

 

 

failure LED.

 

 

Multiple DIMM LEDs do not necessarily indicate

 

 

multiple DIMM failures. If more than one DIMM LED

 

 

is lit, reseat or replace one DIMM at a time until the

 

 

error goes away. Check the system error log in the

 

 

management module for information about the

 

 

error.

 

 

 

Processor x

The processor has failed.

Make sure that the processor that is indicated by

error

 

the lit LED is installed correctly (see “Installing an

 

 

additional processor” on page 25 for installation

 

 

instructions).

 

 

 

Temperature

The system temperature has

• Determine whether a blower on the SBCE unit

error

exceeded a threshold level.

has failed. If it has, replace the fan.

 

 

• Make sure that the room temperature is not too

 

 

high (see “Features and specifications” on

 

 

page 4 for temperature information).

 

 

 

System board

The system board has failed.

Replace the blade server cover, reinsert the blade

error

 

server in the SBCE unit, and then restart the server.

 

 

 

NMI error

The system board has failed.

1. Replace the blade server cover, reinsert the

 

 

blade server in the SBCE unit, and then restart

 

 

the server.

 

 

2. Check the system error log in the management

 

 

module for information about the error.

 

 

 

Processor

The processors do not match.

Make sure that processors 1 and 2 have the same

mismatch

 

cache size and type and the same clock speed.

 

 

Internal and external clock frequencies must be

 

 

identical.

 

 

 

67

Page 81
Image 81
Intel SBX82 manual Light path diagnostics