2. Maximum Inlet Pressure

The following table shows the maximum permissible inlet pressure. However, the actual inlet pressure + pressure against a closed valve must always be lower than the maximum permissible operating pressure.

Pump

Number

Maximum

of Stages

Inlet Pressure

 

1SV

2-16 Stages

250 psi (17 bar)

17-22 Stages

250 psi (17 bar)

 

 

 

 

2SV

2-15 Stages

250 psi (17 bar)

 

 

16-22 Stages

250 psi (17 bar)

 

3SV

2-13 Stages

250 psi (17 bar)

 

 

14-16 Stages

250 psi (17 bar)

 

 

 

 

4SV

2-10 Stages

250 psi (17 bar)

11-12 Stages

250 psi (17 bar)

 

 

 

 

33SV

1-10 Stages

 

 

 

 

46SV

1-10 Stages

250 psi (17 bar)

66SV

1-6 Stages

 

 

 

 

92SV

1-6 Stages

 

 

 

 

3. Maximum Operating Pressure

(staging at 3500 rpm)

Series

At 250º F

PSI / Bar

 

 

 

1SV

2-16 Stages

325 / 25

 

 

17-22 Stages

580 / 40

 

2SV

2-15 Stages

325 / 25

 

 

16-22 Stages

580 / 40

 

 

 

 

3SV

2-13 Stages

325 / 25

14-16 Stages

580 / 40

 

 

 

 

4SV

2-10 Stages

325 / 25

 

 

11-12 Stages

580 / 40

 

33SV

1-6 Stages

362 / 25

 

 

7-10 Stages

580 / 40

 

 

 

 

46SV

1-5 Stages

362 / 25

6-10 Stages

580 / 40

 

 

 

 

66SV

1-5 Stages

362 / 25

 

 

6 Stages

580 / 40

 

92SV

1-5 Stages

362 / 25

 

 

 

NOTE: Oval flange (1-3SV) maximum working pressure is 232 psi (16 bar).

4. Temperature Capability

The SSV pump is capable of pumping liquids within the below temperature range:

1-4SV

-22º F to 250º F (-30º C to 120º C)

33SV-92SV

-22º F to 250º F (-30º C to 120º C)

NOTE: In order to provide adequate cooling for the electric motor, the ambient temperature must be 32º F to 104º F and the relative humidity at 104º F must not exceed 50%.

For temperatures above 104º F and for installations sites located at elevation in excess at 3000 feet above sea level it may be necessary to derate the motor performance. Please contact your distributor/dealer for assistance.

5. Minimum Nominal Flow Rate

To prevent overheating of the internal pump com- ponents, make sure that a minimum water flow is always guaranteed when the pump is running.

For continuous operation the minimum flow rate recommended is specified below.

Pump Size

1SV

2SV

3SV

4SV

Min. Flow

3500 RPM

3

6

12

17

(gpm)

2900 RPM

3

6

10

14

 

 

 

 

 

 

Pump Size

33SV

46SV

66SV

92SV

Min. Flow

3500 RPM

35

40

70

100

(gpm)

2900 RPM

8

10

14

20

NOTE: If this cannot be archived, then a bypass/ recirculate line is recommended.

 

Do not run the pump against a closed

WARNING

 

discharge for longer than a few seconds.

 

6. Number of Starts Per Hour

For electric pumps coupled to motors supplied by Goulds Pumps, the maximum number of work cycles (starts and stops) in one hour are as follows:

HP

3/4-3

5-10

15-20

25-75

# of Starts

5

5

5

5

For more details, refer to technical manual.

 

If you use a different motor from

WARNING

 

the standard one supplied by Goulds

 

Pumps, please consult with the motor manufacturer to find out the maximum number of work cycles allowed.

7. Power Supply Requirements

WARNING Make sure that the supply voltages and frequencies are suited to the

characteristics of the electric motor. Check the motor rating plate.

In general, the supply voltage tolerances for motor operation are as follows:

 

Hz

Phase

 

UN

 

V

 

±%

 

 

 

 

 

60

1

230

 

10

 

60

3

230 / 460

 

10

 

60

3

460

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Transportation and Handling of Packed Product

The SSV pump is packed in cartons or wooden crates having different dimensions and shapes.

 

Some cartons (the supporting base

WARNING

 

is made of wood) are designed to be

 

transported and handled in the vertical position. Other cartons, as well as the wooden crates, are designed to be transported and handled in the hori- zontal position. Protect the product against humid- ity, heat sources and mechanical damage (collisions, falls, ...). Do not place heavy weights on the cartons.