Johnson Controls R-410A manual YJ-15 /Two NH-07 Continued

Models: R-410A

1 100
Download 100 pages 63.88 Kb
Page 32
Image 32
YJ-15 / Two NH-07 (Continued)

505430-BTG-A-0309

YJ-15 / Two NH-07 (Continued)

Air on

 

 

 

 

 

 

Temperature of Air on Condenser Coil

 

 

 

 

 

 

Evaporator Coil

Total

Total

 

Sensible Capacity (MBh)

 

Total

Total

 

Sensible Capacity (MBh)

 

CFM

 

WB

Capacity1

Input

 

Return Dry Bulb (°F)

 

Capacity1

Input

 

Return Dry Bulb (°F)

 

 

(°F)

(MBh)

(kW)2

 

 

 

 

 

 

(MBh)

(kW)2

 

 

 

 

 

 

 

90

85

80

75

70

65

90

85

80

75

70

65

 

 

 

 

 

 

115°F

 

 

 

 

 

 

 

125°F

 

 

 

 

 

 

77

193.0

17.7

96.7

79.6

62.4

-

-

-

188.7

19.3

94.6

77.5

60.3

-

-

-

 

 

72

179.5

17.4

121.8

104.6

87.5

70.3

-

-

175.3

19.0

119.9

102.7

85.5

68.3

-

-

4500

 

67

166.0

17.1

146.9

129.7

112.6

95.4

78.2

-

161.9

18.7

145.1

127.9

110.7

93.5

76.4

-

 

 

62

154.6

16.8

154.6

154.6

137.6

120.4

103.3

86.1

152.9

18.5

152.9

152.9

136.1

118.9

101.7

84.6

 

 

57

151.8

16.8

151.8

151.8

136.4

119.2

102.1

84.9

148.2

18.4

148.2

148.2

132.2

115.1

97.9

80.7

 

 

77

198.9

17.8

105.2

86.0

66.7

-

-

-

193.8

19.4

103.0

83.7

64.5

-

-

-

 

 

72

185.0

17.5

132.0

112.8

93.6

74.3

-

-

180.0

19.1

129.9

110.7

91.5

72.2

-

-

5250

 

67

171.0

17.2

158.9

139.6

120.4

101.2

81.9

-

166.2

18.8

156.9

137.7

118.4

99.2

80.0

-

 

 

62

159.2

16.9

159.2

159.2

147.2

128.0

108.7

89.5

157.1

18.6

157.1

157.1

145.6

126.6

107.1

87.9

 

 

57

156.4

16.9

156.4

156.4

145.9

126.7

107.5

88.2

152.2

18.5

152.2

152.2

141.4

122.6

103.0

83.7

 

 

77

204.7

17.9

113.7

92.4

71.1

-

-

-

198.9

19.5

111.3

90.0

68.7

-

-

-

 

 

72

190.4

17.6

142.3

121.0

99.7

78.4

-

-

184.8

19.2

140.0

118.7

97.4

76.1

-

-

6000

 

67

176.1

17.2

170.9

149.6

128.3

107.0

85.7

-

170.6

18.9

168.7

147.4

126.1

104.9

83.6

-

 

 

62

163.9

17.0

163.9

163.9

156.8

135.5

114.2

92.9

161.3

18.7

161.3

161.3

155.1

134.3

112.5

91.2

 

 

57

161.0

17.0

161.0

161.0

155.4

134.2

112.9

91.6

156.2

18.6

156.2

156.2

150.7

130.2

108.1

86.8

 

 

72

192.4

17.6

149.4

126.5

103.6

80.8

-

-

187.0

19.3

147.1

124.3

101.4

78.6

-

-

6750

 

67

177.9

17.3

175.3

156.2

133.4

110.5

87.7

-

172.7

18.9

171.7

154.2

131.4

108.5

85.7

-

 

62

165.6

17.1

165.6

165.6

162.1

139.2

116.3

93.5

163.2

18.7

163.2

163.2

160.1

137.5

114.4

91.6

 

 

 

 

57

162.6

17.0

162.6

162.6

159.9

137.0

114.1

91.3

158.1

18.7

158.1

158.1

155.3

132.9

109.6

86.8

 

 

72

194.3

17.7

156.5

132.0

107.6

83.2

-

-

189.2

19.3

154.2

129.9

105.5

81.1

-

-

7500

 

67

179.7

17.4

179.7

162.9

138.5

114.1

89.6

-

174.7

19.0

174.7

161.0

136.6

112.2

87.8

-

 

62

167.3

17.1

167.3

167.3

167.3

142.9

118.4

94.0

165.1

18.8

165.1

165.1

165.1

140.7

116.3

92.0

 

 

 

 

57

164.3

17.1

164.3

164.3

164.3

139.8

115.4

91.0

159.9

18.7

159.9

159.9

159.9

135.6

111.2

86.8

1These capacities are gross ratings. For net capacity, deduct supply air blower motor, MBh. Example: Refer to the appropriate Blower Performance Table for the BHP of the supply air blower motor, MBh = 3.415 x kW and kW = BHP x 0.746 nameplate rated motor efficiency.

2These ratings include the condenser fan motors and the compressor motors but not the supply air blower motor.

32

Johnson Controls Unitary Products

Page 32
Image 32
Johnson Controls R-410A manual YJ-15 /Two NH-07 Continued