Johnson Controls R-410A manual Heat Pump And Air Handler Heating Capacities, PH-07 / NH-07

Models: R-410A

1 100
Download 100 pages 63.88 Kb
Page 58
Image 58
Heat Pump And Air Handler Heating Capacities

505430-BTG-A-0309

Heat Pump And Air Handler Heating Capacities

PH-07 / NH-07

Air Over Evaporator Coil

Capacity1 &

 

 

Outdoor Temperature (°F @ 72% RH)

 

 

CFM

DB (°F)

kW

-10

0

10

20

30

40

50

60

 

55

MBH

34.0

39.6

46.2

53.9

62.9

73.5

86.0

100.6

 

KW

4.9

5.3

5.6

6.0

6.3

6.7

7.0

7.3

 

 

2250

70

MBH

31.0

36.6

43.2

50.9

60.0

70.6

83.0

97.6

KW

5.8

6.1

6.5

6.8

7.1

7.5

7.8

8.2

 

 

 

80

MBH

28.7

34.3

40.9

48.6

57.7

68.3

80.7

95.3

 

KW

6.4

6.8

7.1

7.4

7.8

8.1

8.5

8.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

MBH

35.3

40.9

47.5

55.2

64.3

74.9

87.3

101.9

 

KW

4.7

5.1

5.4

5.8

6.1

6.5

6.8

7.1

 

 

3000

70

MBH

32.4

38.0

44.5

52.3

61.3

71.9

84.4

99.0

KW

5.6

5.9

6.3

6.6

6.9

7.3

7.6

8.0

 

 

 

80

MBH

30.1

35.7

42.3

50.0

59.0

69.6

82.1

96.7

 

KW

6.2

6.5

6.9

7.2

7.6

7.9

8.3

8.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

MBH

36.6

42.2

48.8

56.5

65.6

76.2

88.6

103.2

 

KW

5.2

5.6

5.9

6.3

6.6

7.0

7.3

7.6

 

 

3750

70

MBH

33.7

39.3

45.8

53.6

62.6

73.2

85.7

100.3

KW

6.1

6.4

6.8

7.1

7.4

7.8

8.1

8.5

 

 

 

80

MBH

31.4

37.0

43.6

51.3

60.3

70.9

83.4

98.0

 

KW

6.7

7.0

7.4

7.7

8.1

8.4

8.8

9.1

 

 

 

 

 

 

 

 

 

 

 

 

 

1These capacities do not include the supply air blower motor heat. For net capacity, add motor heat, MBh. Example: Refer to the appropriate Blower Performance Table for the BHP of the supply air blower motor, MBh = 3.415 x kW and kW = BHP x 0.746 nameplate rated motor efficiency.

PH-10 / NH-10

Air Over Evaporator Coil

Capacity1 &

 

 

Outdoor Temperature (°F @ 72% RH)

 

 

CFM

DB (°F)

kW

-10

0

10

20

30

40

50

60

 

55

MBH

29.1

36.4

45.3

56.0

69.0

84.7

103.8

126.8

 

KW

6.9

7.3

7.6

8.0

8.3

8.7

9.1

9.4

 

 

3000

70

MBH

26.3

33.6

42.4

53.1

66.1

81.8

100.9

124.0

KW

8.2

8.6

8.9

9.3

9.7

10.0

10.4

10.7

 

 

 

80

MBH

24.2

31.5

40.4

51.1

64.1

79.8

98.8

121.9

 

KW

9.2

9.6

10.0

10.3

10.7

11.1

11.4

11.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

MBH

37.4

44.7

53.5

64.3

77.2

93.0

112.0

135.1

 

KW

6.7

7.1

7.4

7.8

8.1

8.5

8.9

9.2

 

 

4000

70

MBH

34.5

41.8

50.7

61.4

74.4

90.1

109.2

132.2

KW

8.0

8.4

8.7

9.1

9.5

9.8

10.2

10.6

 

 

 

80

MBH

32.5

39.8

48.6

59.3

72.3

88.0

107.1

130.2

 

KW

9.0

9.4

9.8

10.1

10.5

10.9

11.2

11.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

MBH

44.1

51.4

60.3

71.0

84.0

99.7

118.7

141.8

 

KW

6.9

7.2

7.6

8.0

8.3

8.7

9.0

9.4

 

 

5000

70

MBH

41.3

48.6

57.4

68.1

81.1

96.8

115.9

138.9

KW

8.2

8.6

8.9

9.3

9.6

10.0

10.4

10.7

 

 

 

80

MBH

39.2

46.5

55.3

66.1

79.0

94.8

113.8

136.9

 

KW

9.2

9.6

9.9

10.3

10.7

11.0

11.4

11.7

 

 

 

 

 

 

 

 

 

 

 

 

 

1These capacities do not include the supply air blower motor heat. For net capacity, add motor heat, MBh. Example: Refer to the appropriate Blower Performance Table for the BHP of the supply air blower motor, MBh = 3.415 x kW and kW = BHP x 0.746 nameplate rated motor efficiency.