YJ-12 / NJ-15 (Continued)
Air on |
|
|
|
|
|
| Temperature of Air on Condenser Coil |
|
|
|
|
|
|
| ||||||
Evaporator Coil | Total | Total |
| Sensible Capacity (MBh) |
| Total | Total |
| Sensible Capacity (MBh) |
| ||||||||||
CFM |
| WB | Capacity1 | Input |
| Return Dry Bulb (°F) |
|
| Capacity1 | Input |
| Return Dry Bulb (°F) |
|
| ||||||
| (°F) | (MBh) | (kW)2 |
|
|
|
|
|
|
| (MBh) | (kW)2 |
|
|
|
|
|
|
| |
| 90 | 85 | 80 | 75 |
| 70 | 65 | 90 | 85 | 80 | 75 |
| 70 | 65 | ||||||
|
|
|
|
|
| 115°F |
|
|
|
|
|
|
|
| 125°F |
|
|
|
|
|
|
| 77 | 148.6 | 15.3 | 73.8 | 57.6 | 41.4 | - |
| - | - | 134.2 | 17.0 | 69.2 | 53.1 | 36.9 | - |
| - | - |
|
| 72 | 138.6 | 15.1 | 97.6 | 81.4 | 65.3 | 49.1 |
| - | - | 128.0 | 16.7 | 93.8 | 77.6 | 61.5 | 45.3 |
| - | - |
3750 |
| 67 | 128.6 | 14.8 | 121.5 | 105.3 | 89.1 | 72.9 |
| 56.7 | - | 121.7 | 16.3 | 118.3 | 102.2 | 86.0 | 69.9 |
| 53.7 | - |
|
| 62 | 119.7 | 14.5 | 119.7 | 119.7 | 114.2 | 98.0 |
| 81.8 | 65.7 | 111.5 | 16.0 | 111.5 | 111.5 | 110.2 | 94.1 |
| 77.9 | 61.8 |
|
| 57 | 123.4 | 14.7 | 123.4 | 123.4 | 109.0 | 92.8 |
| 76.7 | 60.5 | 115.7 | 16.3 | 115.7 | 115.7 | 101.5 | 85.3 |
| 69.2 | 53.0 |
|
| 77 | 155.4 | 15.4 | 88.5 | 64.6 | 45.9 | - |
| - | - | 142.1 | 17.0 | 86.4 | 60.4 | 41.5 | - |
| - | - |
|
| 72 | 145.0 | 15.1 | 109.7 | 91.0 | 72.3 | 53.6 |
| - | - | 135.4 | 16.6 | 106.7 | 87.8 | 68.9 | 50.0 |
| - | - |
4375 |
| 67 | 134.5 | 14.8 | 130.9 | 117.4 | 98.7 | 80.0 |
| 61.2 | - | 128.7 | 16.3 | 127.0 | 115.2 | 96.4 | 77.5 |
| 58.6 | - |
|
| 62 | 125.3 | 14.5 | 125.3 | 125.3 | 126.5 | 107.8 |
| 89.0 | 70.3 | 118.0 | 16.0 | 118.0 | 118.0 | 118.0 | 105.0 |
| 85.7 | 66.8 |
|
| 57 | 129.1 | 14.7 | 129.1 | 129.1 | 120.7 | 102.0 |
| 83.3 | 64.6 | 122.4 | 16.3 | 122.4 | 122.4 | 113.8 | 95.2 |
| 76.0 | 57.1 |
|
| 77 | 162.3 | 15.4 | 103.2 | 71.6 | 50.3 | - |
| - | - | 150.0 | 16.9 | 103.5 | 67.6 | 46.0 | - |
| - | - |
|
| 72 | 151.3 | 15.1 | 121.8 | 100.6 | 79.3 | 58.0 |
| - | - | 142.8 | 16.6 | 119.6 | 98.0 | 76.3 | 54.7 |
| - | - |
5000 |
| 67 | 140.4 | 14.8 | 140.4 | 129.5 | 108.3 | 87.0 |
| 65.7 | - | 135.6 | 16.3 | 135.6 | 128.3 | 106.7 | 85.1 |
| 63.5 | - |
|
| 62 | 130.8 | 14.5 | 130.8 | 130.8 | 138.8 | 117.5 |
| 96.2 | 75.0 | 124.4 | 16.0 | 124.4 | 124.4 | 124.4 | 115.8 |
| 93.5 | 71.9 |
|
| 57 | 134.8 | 14.7 | 134.8 | 134.8 | 132.5 | 111.2 |
| 90.0 | 68.7 | 129.0 | 16.2 | 129.0 | 129.0 | 126.0 | 105.2 |
| 82.8 | 61.2 |
|
| 72 | 154.3 | 15.2 | 133.5 | 110.3 | 87.0 | 63.8 |
| - | - | 144.6 | 16.7 | 130.8 | 107.3 | 83.8 | 60.3 |
| - | - |
5625 |
| 67 | 143.2 | 14.9 | 143.2 | 137.8 | 118.8 | 95.5 |
| 72.3 | - | 137.4 | 16.4 | 137.4 | 134.1 | 117.1 | 93.6 |
| 70.1 | - |
| 62 | 133.4 | 14.6 | 133.4 | 133.4 | 137.4 | 114.1 |
| 90.8 | 67.6 | 126.0 | 16.1 | 126.0 | 126.0 | 126.0 | 109.0 |
| 85.1 | 61.6 | |
|
|
|
| |||||||||||||||||
|
| 57 | 137.4 | 14.8 | 137.4 | 137.4 | 136.3 | 113.0 |
| 89.8 | 66.5 | 130.7 | 16.3 | 130.7 | 130.7 | 129.2 | 106.1 |
| 82.2 | 58.7 |
|
| 72 | 157.3 | 15.3 | 145.3 | 120.0 | 94.7 | 69.5 |
| - | - | 146.4 | 16.8 | 142.0 | 116.6 | 91.2 | 65.8 |
| - | - |
6250 |
| 67 | 146.0 | 15.0 | 146.0 | 146.0 | 129.3 | 104.1 |
| 78.8 | - | 139.2 | 16.5 | 139.2 | 139.2 | 127.5 | 102.1 |
| 76.7 | - |
| 62 | 136.0 | 14.7 | 136.0 | 136.0 | 136.0 | 110.7 |
| 85.4 | 60.2 | 127.6 | 16.2 | 127.6 | 127.6 | 127.6 | 102.2 |
| 76.8 | 51.4 | |
|
|
|
| |||||||||||||||||
|
| 57 | 140.1 | 14.9 | 140.1 | 140.1 | 140.1 | 114.8 |
| 89.6 | 64.3 | 132.4 | 16.5 | 132.4 | 132.4 | 132.4 | 107.0 |
| 81.6 | 56.2 |
1These capacities are gross ratings. For net capacity, deduct supply air blower motor, MBh. Example: Refer to the appropriate Blower Performance Table for the BHP of the supply air blower motor, MBh = 3.415 x kW and kW = BHP x 0.746 ⎟ nameplate rated motor efficiency.
2These ratings include the condenser fan motors and the compressor motors but not the supply air blower motor.
26 | Johnson Controls Unitary Products |