Air Over Evaporator Coil | Capacity1 & |
|
| Outdoor Temperature (°F @ 72% RH) |
|
| |||||
CFM | DB (°F) | kW | 0 | 10 | 20 | 30 | 40 | 50 | 60 | ||
|
|
|
|
|
|
|
|
|
|
| |
| 55 | MBH | 84.3 | 98.8 | 115.6 | 135.0 | 157.4 | 183.2 | 212.9 | 247.3 | |
| KW | 13.7 | 14.4 | 15.2 | 15.9 | 16.6 | 17.3 | 18.1 | 18.8 | ||
|
| ||||||||||
6000 | 70 | MBH | 90.0 | 104.5 | 121.3 | 140.7 | 163.1 | 188.8 | 218.6 | 253.0 | |
KW | 16.1 | 16.8 | 17.6 | 18.3 | 19.0 | 19.7 | 20.5 | 21.2 | |||
|
| ||||||||||
| 80 | MBH | 88.3 | 102.8 | 119.6 | 139.0 | 161.3 | 187.1 | 216.9 | 251.2 | |
| KW | 17.8 | 18.5 | 19.3 | 20.0 | 20.7 | 21.5 | 22.2 | 22.9 | ||
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| |
| 55 | MBH | 88.8 | 103.4 | 120.2 | 139.5 | 161.9 | 187.7 | 217.4 | 251.8 | |
| KW | 13.2 | 13.9 | 14.7 | 15.4 | 16.1 | 16.8 | 17.6 | 18.3 | ||
|
| ||||||||||
8000 | 70 | MBH | 94.5 | 109.1 | 125.8 | 145.2 | 167.6 | 193.4 | 223.1 | 257.5 | |
KW | 15.6 | 16.3 | 17.0 | 17.8 | 18.5 | 19.2 | 19.9 | 20.7 | |||
|
| ||||||||||
| 80 | MBH | 92.8 | 107.3 | 124.1 | 143.5 | 165.9 | 191.6 | 221.4 | 255.8 | |
| KW | 17.3 | 18.0 | 18.8 | 19.5 | 20.2 | 20.9 | 21.7 | 22.4 | ||
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| |
| 55 | MBH | 92.3 | 106.8 | 123.6 | 143.0 | 165.3 | 191.1 | 220.9 | 255.2 | |
| KW | 14.5 | 15.3 | 16.0 | 16.7 | 17.4 | 18.2 | 18.9 | 19.6 | ||
|
| ||||||||||
9000 | 70 | MBH | 97.9 | 112.5 | 129.3 | 148.7 | 171.0 | 196.8 | 226.6 | 260.9 | |
KW | 16.9 | 17.7 | 18.4 | 19.1 | 19.8 | 20.6 | 21.3 | 22.0 | |||
|
| ||||||||||
| 80 | MBH | 96.2 | 110.8 | 127.6 | 146.9 | 169.3 | 195.1 | 224.8 | 259.2 | |
| KW | 18.7 | 19.4 | 20.1 | 20.8 | 21.6 | 22.3 | 23.0 | 23.7 | ||
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
1These capacities do not include the supply air blower motor heat. For net capacity, add motor heat, MBh. Example: Refer to the appropriate Blower Performance Table for the BHP of the supply air blower motor, MBh = 3.415 x kW and kW = BHP x 0.746 ⎟ nameplate rated motor efficiency.
Air Over Evaporator Coil | Capacity1 & |
|
| Outdoor Temperature (°F @ 72% RH) |
|
| |||||
CFM | DB (°F) | kW | 0 | 10 | 20 | 30 | 40 | 50 | 60 | ||
| 55 | MBH | 64.6 | 79.5 | 97.4 | 118.8 | 144.3 | 174.9 | 211.4 | 255.1 | |
| KW | 15.7 | 16.5 | 17.3 | 18.1 | 19.0 | 19.8 | 20.6 | 21.4 | ||
|
| ||||||||||
6000 | 70 | MBH | 69.5 | 84.4 | 102.3 | 123.7 | 149.2 | 179.8 | 216.3 | 260.0 | |
KW | 15.4 | 16.2 | 17.0 | 17.9 | 18.7 | 19.5 | 20.3 | 21.2 | |||
|
| ||||||||||
| 80 | MBH | 63.3 | 78.3 | 96.2 | 117.5 | 143.1 | 173.6 | 210.2 | 253.8 | |
| KW | 17.2 | 18.0 | 18.8 | 19.6 | 20.5 | 21.3 | 22.1 | 23.0 | ||
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| |
| 55 | MBH | 71.6 | 86.6 | 104.5 | 125.8 | 151.4 | 181.9 | 218.5 | 262.1 | |
| KW | 15.1 | 15.9 | 16.8 | 17.6 | 18.4 | 19.2 | 20.1 | 20.9 | ||
|
| ||||||||||
8000 | 70 | MBH | 76.5 | 91.5 | 109.4 | 130.7 | 156.3 | 186.8 | 223.4 | 267.0 | |
KW | 14.8 | 15.6 | 16.5 | 17.3 | 18.1 | 19.0 | 19.8 | 20.6 | |||
|
| ||||||||||
| 80 | MBH | 70.4 | 85.3 | 103.2 | 124.6 | 150.1 | 180.7 | 217.2 | 260.9 | |
| KW | 16.6 | 17.4 | 18.3 | 19.1 | 19.9 | 20.7 | 21.6 | 22.4 | ||
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| |
| 55 | MBH | 73.3 | 88.3 | 106.1 | 127.5 | 153.1 | 183.6 | 220.1 | 263.8 | |
| KW | 15.3 | 16.1 | 17.0 | 17.8 | 18.6 | 19.4 | 20.3 | 21.1 | ||
|
| ||||||||||
10000 | 70 | MBH | 78.2 | 93.2 | 111.0 | 132.4 | 158.0 | 188.5 | 225.0 | 268.7 | |
KW | 15.0 | 15.8 | 16.7 | 17.5 | 18.3 | 19.1 | 20.0 | 20.8 | |||
|
| ||||||||||
| 80 | MBH | 72.1 | 87.0 | 104.9 | 126.3 | 151.8 | 182.4 | 218.9 | 262.6 | |
| KW | 16.8 | 17.6 | 18.5 | 19.3 | 20.1 | 20.9 | 21.8 | 22.6 | ||
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
1These capacities do not include the supply air blower motor heat. For net capacity, add motor heat, MBh. Example: Refer to the appropriate Blower Performance Table for the BHP of the supply air blower motor, MBh = 3.415 x kW and kW = BHP x 0.746 ⎟ nameplate rated motor efficiency.