7: Network, Line, Tunnel, and Terminal Settings

 

 

Tunnel – Packing Mode Page

 

 

 

 

 

 

Tunnel – Packing

Description

 

 

Mode Page

 

 

 

Settings

 

 

 

Mode

Select the method used to pack data. Choices are:

 

 

 

Disabled = default packing algorithm. (default)

 

 

 

Timeout = data is sent after the timeout elapses.

 

 

 

Send Character = data is sent when the send character is read on

 

 

 

the serial line.

 

 

 

 

 

 

Timeout

Enter the maximum number of milliseconds to wait before sending

 

 

 

queued data across the network. Default is 1000 milliseconds.

 

 

 

 

 

 

Threshold

Enter the queued data limit that, when reached, immediately sends

 

 

 

queued data to the network. Default is 512 bytes.

 

 

Send Character

Enter the send character. When this character is read on the serial

 

 

 

line, it forces the queued data to be sent immediately. Default is

 

 

 

<none>.

 

 

Trailing Character

Enter the trailing character. This character is inserted into the

 

 

 

outgoing data stream immediately after the send character. Default is

 

 

 

<none>.

 

Tunnel – Modem Emulation Page

A tunnel in connect mode can be initiated using modem commands incoming from the serial line. If you click Modem Emulation at the top of one of the Tunnel pages, the Tunnel – Modem Emulation page displays. Here you can select modem emulation settings for the tunnel selected at the top of the page. For more information about modem emulation, see Modem Emulation on page 164.Tunnel – Modem Emulation Page

EDS Device Servers User Guide

69

Page 69
Image 69
Lantronix EDS16PR, EDS32PR, EDS4100, EDS8PR manual Tunnel Modem Emulation, Tunnel Packing Description Mode Settings