2. ICEMAKER FUNCTIONS

ICEMAKER AND DISPENSER WORKING PRINCIPLES AND REPAIR

2. ICEMAKER FUNCTIONS

2-1. Start Position

1.After POWER OFF or power outage, check the EJECTOR's position with MICOM initialization to restart.

2.How to check if it is in place:

-Check HIGH/LOW signals from HALL SENSOR in MICOM PIN.

3.Control Method to check if it is in place:

(1) EJECTOR is in place,

-It is an initialized control, so the mode can be changed to icemaking mode.

(2)EJECTOR isn't in place:

A.If EJECTOR is back in place within 2 minutes with the motor on, it is being initialized. If not, go to Step B.

B.Control the heater using the temperature sensor until the EJECTOR reaches the correct location.

2-2. Icemaking Mode

1.Icemaking refers to the freezing of supplied water in the ice tray. Complete freezing is assured by measuring the temperature of the Tray with Icemaking SENSOR.

2.Icemaking starts after completion of the water fill operation.

3.The Ice Making function is completed when the sensor reaches 19°F (-7°C), 55 minutes after starting.

NOTE : After Icemaker Power is ON, the Icemaker heater will be on for test for 6 sec.

2-3. Harvest Mode

1.Harvest (Ice removing) refers to the operation of dropping ices into the ice bin from the tray when icemaking has completed.

2.Harvest mode:

(1)The Heater is ON for 30 seconds, then the motor starts.

(2)The feeler arm senses the quantity of ice in the ice bin while rotating with the EJECTOR.

A.ice bin is full : The EJECTOR stops (heater off).

B.ice bin is not full : The EJECTOR rotates twice to open for ice.

2-1. Start Position If the EJECTOR does not rotate once within 5 minutes in B mode, separate heater control mode starts operating to prevent the EJECTOR from being constrained. (It is recommended that the user open for ice to return to normal mode.)

2-4. Fill/Park Position

1.Once a normal harvest mode has been completed, the water solenoid will be activated.

2.The amount of water is adjusted by pressing the Fill Key repeatedly. This changes the time allowed for fill as illustrated in the table below.

Water supply amount TABLE

STAGE

TIME TO SUPPLY

INDICATIONS

REMARKS

 

 

 

 

 

 

 

 

 

1

5 sec.

 

 

 

 

 

 

The water amount will vary depending

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

5.5 sec.

 

 

 

 

 

 

on the water control switch setting, as

 

 

 

 

 

 

 

(FIRST STAGE)

 

 

 

 

 

 

well as the water pressure of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connected water line.

3

6 sec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 42 -