LG Electronics GR-P257/L257 Trouble Diagnosis, Claims, Causes And Check Points, How To Check

Models: GR-P257/L257 GR-P227/L227

1 99
Download 99 pages 61.41 Kb
Page 51
Image 51
constrained.

TROUBLE DIAGNOSIS

CLAIMS.

 

 

 

 

CAUSES AND CHECK POINTS.

HOW TO CHECK

 

 

 

 

 

 

 

 

 

 

 

 

3. Refrigeration

4) No cooling air circulation.

 

 

 

 

 

is weak.

 

 

Faulty fan motor.

 

Fan is

 

 

 

Fan shroud contact. - Clearance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

constrained.

 

 

 

Damping evaporator contact.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accumulated residual frost.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Small cooling air

 

Insufficient

 

 

 

Fan overload. - Fan misuse.

 

 

 

 

discharge.

 

motor RPM

 

 

 

Bad low termperature RPM characteristics.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated power misuse.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Faulty fan.

 

 

 

 

Low voltage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan misuse.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bad shape.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loose connection. - Not tightly connected.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Insert depth.

 

 

 

 

 

 

 

 

 

 

Shorud. Bent.

Ice and foreign materials on rotating parts.

5)Compressor capacity. Small cooling air Rating misuse. Small capacity. Low valtage.

6)

Refrigerant

 

 

 

Malfunction of charging cylinder.

 

 

 

 

 

 

too much or too little.

 

 

 

Wrong setting of refrigerant.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Insufficient compressor. - Faulty compressor.

 

 

 

 

 

 

 

 

 

 

 

 

7)

Continuous operation

 

 

- No contact of temperature controller. - Foreign materials.

 

 

Check visually after

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

disassembly.

8)

Damper opens continuously.

 

 

 

 

Foreign materials

 

 

 

 

P/U liquid dump.

Check visually after

 

 

 

 

 

 

 

 

 

 

jammed.

 

 

 

 

EPS water sediment.

disassembly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screw.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Failed sensor. - Position of sensor.

 

 

 

 

 

 

 

 

Characteristics

 

 

 

Bad characteristics of its own temperatue.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of damper.

 

 

 

Parts misuse.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Charge of temperature - Impact.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

characteristics.

 

9)

Food storing place. - Near the outlet of cooling air.

 

 

 

 

 

 

 

 

 

 

 

 

 

- 49 -

Page 51
Image 51
LG Electronics GR-P257/L257 Trouble Diagnosis, Claims, Causes And Check Points, How To Check, Small cooling air, motor RPM