LG Electronics GR-P227/L227 Cooling Cycle Heavy Repair, Trouble Diagnosis, Items, Unit, Standards

Models: GR-P257/L257 GR-P227/L227

1 99
Download 99 pages 61.41 Kb
Page 74
Image 74
3. Cooling Cycle Heavy Repair

TROUBLE DIAGNOSIS

3. Cooling Cycle Heavy Repair

3-1. The Heavy Repair Standards for Refrigerator with R134a Refrigerant

NO.

Items

Unit

Standards

Purposes

Remarks

1

Pipe and piping

Min.

Pipe:within 1 hour.

To protect

The opening time should be reduced to a

 

system opening time.

 

Comp:within

Moisture

half of the standards during rain and

 

 

 

 

 

10 minutes.

Penetration.

rainy seasons (the penetration of water

 

 

 

 

 

Drier:within

 

into the pipe is dangerous).

 

 

 

 

 

20 minutes.

 

 

2

Welding.

 

Nitrogen

Weld under

To protect

- Refet to repair note in each part.

 

 

 

 

Pressure.

Nitrogen

oxide scale

- R134a refrigerant is more susceptible to

 

 

 

 

 

atmosphere

formation.

leaks than R12 and requires more care

 

 

 

 

 

(N2 pressure:

 

during welding.

 

 

 

 

 

0.1~0.2 kg/cm2)

 

- Do not apply force to pipes before and

 

 

 

 

 

 

 

after welding to protect pipe from

 

 

 

 

 

 

 

cracking.

3

N2 sealed parts.

Confirm N2

Confirm air leaking

To protect

- In case of evaporator parts, if it doesn't

 

 

 

 

leak.

sounds when

moisture

noise when removing rubber cap blow

 

 

 

 

 

removing rubber

penetration.

dry air or N2 gas for more than 1 min

 

 

 

 

 

cap.

 

use the parts.

 

 

 

 

 

Sound:usable

 

 

 

 

 

 

 

No sound:not usable

 

 

4

Refrigeration

 

Evacuation

Min.

More than

To remove

 

 

Cycle.

 

time

 

40 minutes.

moisture.

 

 

 

 

Vacuum

Torr

Below 0.03(ref)

 

Note:Only applicable to the model

 

 

 

degree

 

 

 

equipped with reverse flow protect

 

 

 

 

 

 

 

plate.

 

 

 

Vacuum

EA

High and low

 

Vaccum efficiency can be improved by

 

 

 

 

 

Pressure sides are

 

operating compressor during evacuation.

 

 

 

 

 

evacuated at the

 

 

 

 

 

 

 

same time for

 

 

 

 

 

 

 

models above 200L

 

 

 

 

 

Vacuum

EA

Use R134a

To protect

The rubber pipes for R12 refrigerant shall

 

 

 

piping

 

exclusive

mixing of

be melted when they are used for R134a

 

 

 

 

 

manifold.

mineral and

refrigerant(causes of leak).

 

 

 

 

 

 

ester oils.

 

 

 

 

Pipe

EA

Use R134a

To protect

 

 

 

 

coupler

 

cxclusive.

R12 Refri-

 

 

 

 

 

 

 

gerant mixing.

 

 

 

 

Outlet

 

R134a exclusive.

 

 

 

 

 

(Socket)

 

 

 

 

 

 

 

Plug

 

R134a exclusive

 

 

5

Refrigerant weighing.

EA

Use R134a

Do not mix

- Do not weight the refrigerant at too hot or

 

 

 

 

 

exclusively.

with R12

too cold an area.(25°C is adequate.)

 

 

 

 

 

Weighing

refrigerant.

- Use copper bombe

 

 

 

 

 

allowance:±5g

 

Socket:2SV Plug: 2PV R134a

 

 

 

 

 

Note:Winter:-5g

 

Note:Do not burn O-ring (rubber) during

 

 

 

 

 

Summer:+5g

 

welding.

6

Drier replacement.

 

-Use R134a exclusively

To remove

 

 

 

 

 

 

for R134a refrigerator

the moisture

 

 

 

 

 

 

-Use R12 exclusively

from pipe.

 

 

 

 

 

 

for R12 refrigerator

 

 

 

 

 

 

 

-Replace drier whenever

 

 

 

 

 

 

 

repairing refrigerator

 

 

 

 

 

 

 

cycle piping.

 

 

7

Leak check.

 

 

-Do not use soapy

Detect

-Check oil leak at refrigerant leak area.

 

 

 

 

 

water for check.

refrigerant

Use electronic leak detector if oil leak is

 

 

 

 

 

it may be sucked

leak area.

not found.

 

 

 

 

 

into the pipe by.

 

-The electronic leak detector is very

 

 

 

 

 

 

 

sensitive to halogen gas in the air. It also

 

 

 

 

 

 

 

can detect R141b in urethane. Please

 

 

 

 

 

 

 

practice, therfore, many times before use.

 

 

 

 

 

 

 

 

NOTE) Please contact Songso company on +82-53-554-2067 if you have inquiry on heavy repair special facility.