LG Electronics GR-P257/L257 Faults, Power, Compressor, Trouble Diagnosis, Problems, Causes

Models: GR-P257/L257 GR-P227/L227

1 99
Download 99 pages 61.41 Kb
Page 57
Image 57
2. Faults

2. Faults

2-1. Power

 

Problems

Causes

 

 

 

Checks
Measures

Remarks

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No power on

- Power cord cut.

- Check the voltage with tester.

-Replace the components.

 

 

outlet.

- Faulty connector insertion.

- Check visually.

-Reconnect the connecting parts.

 

 

 

- Faulty connection between plug

- Check visually.

- Reconnect the connecting parts.

 

 

 

and adapter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fuse blows out.

- Short circuit by wrong connection.

- Check the fuse with tester

- Find and remove the cause of

- Replace with rated

 

 

- Low voltage products are

or visually.

problem(ex. short, high voltage,

fuse after confirming

 

 

connected to high voltage.

- Check the input volt are with tester

low voltage).

its specification.

 

 

- Short circuit by insects.

(between power cord and products).

- Replace with rated fuse.

 

 

 

- Electricity leakage.

- Check the resistance of power cord

 

If fuse blowns out

 

 

- High voltage.

with testerf (if it is 0, it is shorted).

 

frequently, reconfirm

 

 

- Short circuit of components

 

 

 

 

 

 

 

 

 

 

 

 

 

the cause and prevent.

-

 

(tracking due to moisture and dust

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55 -

 

penetration).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-2. Compressor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Problems

Causes

 

 

 

Checks

Measures

Remarks

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor

- Faulty PTC.

- Check the resistance.

- If resistance is infinite, replace it

 

 

does not

 

Vlaue:is defective.

with new one.

 

 

operate.

 

 

 

 

 

 

 

 

 

 

 

 

 

- If it is not infinite, it is normal.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Check other parts.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Compressor is frozen.

- If compressor assembly parts are

- During forced operation:

 

 

 

 

normal(capacitor, PTC, OLP),

- Operates: Check other parts.

 

 

 

 

apply power directly to the

- Not operate: Replace the frozen

 

 

 

 

compressor to force operation.

compressor with new one, weld,

 

 

 

 

 

 

 

 

Auxiliary winding

 

 

 

 

 

evacuate, and recharge refrigerant.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Main winding

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OLP

 

It starts as soon as it is

• Refer to weld repair procedures.

 

 

 

 

 

 

contacted.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TROUBLE DIAGNOSIS

Page 57
Image 57
LG Electronics GR-P257/L257 Faults, Power, Compressor, Trouble Diagnosis, Problems, Causes, Checks, Measures, Remarks