Insufficient drier

TROUBLE DIAGNOSIS

CLAIMS.

 

 

 

 

 

 

 

 

 

CAUSES AND CHECK POINTS.

HOW TO CHECK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. No cooling.

2) Refrigeration system is clogged.

 

 

 

 

 

 

 

 

 

 

 

Check the clogged

 

 

 

 

Moisture

 

 

 

Residual moisture

 

 

 

 

Air Blowing.

 

 

Not performed.

evaporator by heating (as

 

 

 

 

 

 

 

 

 

 

 

 

 

soon as the cracking sound

 

 

 

 

clogged.

 

 

 

in the evaporator.

 

 

 

 

 

 

 

 

Too short.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

begins, the evaporator start

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Impossible moisture

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

freezing)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

confirmation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low air pressure.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Leave it in the air.

 

 

 

During rest time.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Caps are missed.

 

 

 

After work.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Residual moisture.

 

 

 

 

Not dried in the compressor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Elapsed more than 6 months after drying

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Caps are missed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Insufficient drier

 

 

 

 

 

 

No pressure when it is open.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No electric

 

 

 

 

 

 

 

 

 

Dry drier - Drier temperature.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

power on

 

 

 

capacity.

 

 

 

 

 

 

Leave it in the air.

 

 

 

Check on package

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

therm-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

condition.

 

 

 

 

 

ostat.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Good storage after

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

finishing.

 

 

 

 

 

 

 

 

 

Residual moisture

 

 

 

 

 

Caps are missed.

 

 

 

 

During transportation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in pipes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

During work.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air blowing.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Not performed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Performed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Too short time.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low air pressure.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Less dry air.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Moisture penetration - Leave it in the air. - Moisture penetration.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

into the refrigeration oil.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The evaporator does not cool

 

 

 

 

Weld joint

 

 

 

Short pipe insert.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

from the beginnig (no evidece

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pipe gaps.

 

 

Too large.

 

 

 

 

 

 

 

 

 

 

 

of misture attached).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

clogged.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Damaged pipes.

 

 

 

 

 

 

 

 

 

 

 

The evaporator is the same

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Too much solder.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

as before even heat is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

applied.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drier cloggeing.

 

The capillary tube inserted depth. - Too much.

 

 

 

 

 

 

 

 

 

 

 

 

Capillary tube melts. - Over heat.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clogged with foreign materials.

 

 

 

Desiccant powder.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weld oxides.

Drier angle.

Reduced cross section by cutting. - Squeezed.

Foreign material clogging.

 

 

Compressor cap is disconnected.

 

 

 

Foreign materials are in the pipe.

 

 

 

- 46 -