ICEMAKER AND DISPENSER WORKING PRINCIPLES AND REPAIR

2-5. Function TEST

1.This is a forced operation for TEST, Service, cleaning, etc. It is operated by pressing and holding the Water amount selection button for 3 seconds.

2.The test works only in the Icemaking Mode. It cannot be entered from the Harvest or Fill mode. (If there is an ERROR, it can only be checked in the TEST mode.)

3.Caution! If the test is performed before water in the ice tray is frozen, the ejector will just pass through the water. When the Fill mode begins (Stage 4), unless the water supply has been shut off, added water will overflow into the ice bin. If the control doesn’t operate normally in the TEST mode, check and repair as needed.

4.After water is supplied, the normal CYCLE is followed: icemaking Harvest Fill Park Position.

5.After Stage 5 is completed, the Ice Maker returns to MICOM control. The time needed to supply water resets to the pre- test setting.

6.This icemaker function test takes about 90 seconds in case, there aren’t ices in the ice tray. If there are ices in the ice tray, it can take more than 90 seconds.

Diagnosis TABLE

STAGE

ITEMS

INDICATOR

REMARKS

 

 

 

 

 

 

 

 

 

 

1

HEATER

 

 

 

 

 

 

 

Five seconds after heater starts, a

 

 

 

 

 

 

 

heater will go off if the temperature by

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

sensor is higher than 10°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

MOTOR

 

 

 

 

 

 

 

Five seconds after heater starts, you

 

 

 

 

 

 

 

 

 

 

 

 

 

 

can confirm that a motor is moving.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HALL IC I

 

 

 

 

 

 

 

After the icemaker detects that ice has been

3

(detection of

 

 

 

 

 

 

 

made, the motor and heater are off but on

 

 

 

 

 

 

 

 

position)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

standby until the cycle is cancelled.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

HALL IC II

 

 

 

 

 

 

 

You can confirm HALL IC detection of

(detection of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

position.

 

 

 

 

 

 

 

 

position)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

VALVE

 

 

 

 

 

 

 

Two seconds after detection of initial

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

position, you can confirm that valve is on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Reset

Return to Status prior to

Five seconds after fifth stage is completed,

TEST MODE

The icemaker resets to initial status.

 

 

 

 

 

 

 

 

 

 

 

 

3. Defect diagnosis function

3-1. ERROR CODES shown on Icemaker water supply control panel

NO

DIVISION

INDICATOR

CONTENTS

REMARKS

 

 

 

 

 

 

 

 

 

 

 

 

1

Normal

Mark time to

None

Display switch

 

supply

operates properly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Icemaking

 

 

 

 

 

 

 

Open or short-circuited wire

Make sure that the wire

 

 

 

 

 

 

 

Sensor

 

 

 

 

 

 

 

on each sensor is

 

malfunction

 

 

 

 

 

 

 

 

connected.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ERROR indicators in table can be checked only in TEST mode.

- 43 -

Page 45
Image 45
LG Electronics GR-P257/L257, GR-P227/L227 service manual Defect diagnosis function, Stage Items Indicator Remarks