- 57 -
2-4. Cooling
Problems | Causes |
| Checks | Measures | Remarks |
|
|
|
|
| |
High | Refrigerant leak. | Check sequence | Weld the leaking part, recharge the | Drier must be replaced. | |
temperature |
| 1. | Check the welded parts of the | refrigerant. |
|
in the freezer |
|
| drier inlet and outlet and drier |
|
|
compartment. |
|
| auxiliary in the compressor |
|
|
|
|
| compartment (high pressure side). |
|
|
|
| 2. | Check the end of compressor |
|
|
|
|
| sealing pipe (low pressure side). |
|
|
|
| 3. | Check silver soldered parts. |
|
|
|
|
| (Cu + Fe / Fe + Fe). |
|
|
|
| 4. | Check bending area of wire |
|
|
|
|
| condenser pipe in compressor |
|
|
|
|
| compartment (cracks can |
|
|
|
|
| happen during bending). |
|
|
|
| 5. | Check other parts (compressor |
|
|
|
|
| compartment and evaporators in |
|
|
|
|
| freezer compartment). |
|
|
|
|
|
|
| |
| Shortage of refrigerant. | Check frost formation on the surface | - Find out the leaking area, repair, | Drier must be replaced. | |
|
| of evaporator in the freezer | evacuate, and recharge the |
| |
|
| compartment. | refrigerant. |
| |
|
| - If the frost forms evenly on the | - No leaking, remove the remaining |
| |
|
| surface, it is OK. | refrigerant, and recharge new |
| |
|
| - If it does not, it is not good. | refrigerant. |
| |
|
|
|
|
|
|