TROUBLE DIAGNOSIS

CLAIMS.

CAUSES AND CHECK POINTS.

 

HOW TO CHECK

 

 

 

 

 

 

 

 

 

3. Refrigeration

1) Refrigerant Partly leaked.

 

 

Weld joint leak.

 

 

 

 

 

 

 

 

 

 

is weak.

2) Poor defrosting capacity.

 

 

 

Parts leak.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check visually.

 

 

Drain path (pipe) clogged.

 

Inject P/U into drain hose.

 

 

 

 

 

Inject through the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

hole.

 

 

 

 

 

 

 

 

 

 

Seal with drain.

 

 

 

 

 

 

Foreign materials

P/U lump input.

 

 

 

 

 

 

penetration.

Screw input.

 

 

 

 

 

 

 

 

 

Other foreign materials

 

 

 

 

 

 

 

 

 

input.

 

 

 

 

 

 

 

Cap drain is not disconnected.

 

 

 

 

Defrost heater does not

Parts

Heater

Wire is cut.

 

Check terminal

 

 

generate heat.

disconnected.

Sheath

- Lead wire.

 

 

 

 

Conduction: OK.

 

 

 

 

 

 

 

 

- Heating wire.

 

 

 

 

 

 

 

 

 

 

No conduction: NG.

 

 

 

 

 

 

 

 

- Contact point

 

 

 

 

 

 

 

 

 

 

If wire is not cut, refer to

 

 

 

 

 

 

 

 

between heating and

 

 

 

 

 

 

 

 

 

 

resistance.

 

 

 

 

 

 

 

 

electric wire.

 

 

 

 

 

 

 

 

 

 

P=Power

 

 

 

 

 

 

 

 

Dent by fin evaporator.

 

 

 

 

 

 

 

 

 

 

V=Voltage

 

 

 

 

 

 

 

 

Heating wire is corroded

 

 

 

 

 

 

 

 

 

 

R=Resistance

 

 

 

 

 

 

 

 

- Water penetration.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bad terminal connection.

 

V2

 

 

 

 

 

 

 

 

 

 

P= —

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

V2

 

 

 

 

 

 

 

 

 

 

R= —

 

 

 

 

 

 

 

 

 

 

P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 47 -

Page 49
Image 49
LG Electronics GR-P257/L257, GR-P227/L227 service manual Refrigeration