- 56 -
2-3. Temperature
Problems | Causes | Checks | Measures | Remarks |
|
|
|
|
|
High | Poor cool air circulation due to faulty | - Lock | - Replace fan motor. |
|
temperature | fan motor. | tester. |
|
|
in the freezer |
| 0Ω: short. |
|
|
compartment. |
| ∞Ω: cut. | - Reconnect and reinsert. |
|
|
| - Rotate rotor manually and check |
|
|
|
| rotation. |
|
|
|
| - Wire is cut. |
|
|
|
| - Bad terminal contact: Check | - Maintain clearance and remove ice |
|
|
| terminal visually. | (Repair and/or replace shroud if fan |
|
|
| - Fan constraint. – Fan shroud | is constrained by shroud |
|
|
| contact: Confirm | deformation). |
|
|
| visually. |
|
|
|
| – Fan icing: |
|
|
|
| Confirm visually. |
|
|
|
|
|
|
|
| Faulty fan motor due to faulty door | - Iced button (faulty) operation: | - Confirm icing causes and repair. |
|
| switch operation. | Press button to check | - Replace door switch. |
|
|
| - Faulty button pressure and contact: |
|
|
|
| Press button to check operation. |
|
|
|
| - Door cannot press door switch | - Door sag: fix door. |
|
|
| button: Check visually. | - Door liner bent:replace door or |
|
|
|
| attach sheets. |
|
|
|
|
|
|
| Bad radiation conditions in | - Check the clearance between the | - Keep clearance between | - The fan may be |
| compressor compartment. | refrigerator and wall (50 mm in | refrigerator and walls (minimum | broken if cleaning |
|
| minimum). | 50mm). | performs while the |
|
| - Check dust on the grill in | - Remove dust and contaminants | refrigerator is on. |
|
| compressor compartment. | from grill for easy heat radiation. |
|
|
| - Check dust on the coils condenser. | - Remove the dust with vacuum |
|
|
|
| cleaner from the coils condenser |
|
|
|
| while the refrigerator is off. |
|
|
|
|
|
|