A-1

 

 

 

SPECIFICATIONS

 

A-1

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS - POWER WAVE® AC/DC 1000 (K2344-1, K2344-2)

 

 

 

 

 

 

 

 

 

 

INPUT AT RATED OUTPUT - THREE PHASE ONLY

 

INPUT VOLTS

INPUT

OUTPUT

IDLE

POWER FACTOR

EFFICIENCY

3 PHASE

CURRENT

AMPS

CONDITIONS

POWER

@ RATED OUTPUT

@ RATED OUTPUT

50/60 Hz

K2344-1

K2344-2

 

WATTS

 

 

380

---

82

 

 

 

 

400

---

79

1000A@44V.

 

 

 

460

68

69

100% Duty Cycle

225

.95

86%

500

62

62

 

 

 

 

575

54

55

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

OPEN

AUXILIARY

POWER

 

PROCESS CURRENT RANGES (AC or DC)

CIRCUIT

 

(CIRCUIT BREAKER

 

 

 

 

 

 

 

 

VOLTAGE

 

PROTECTED)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25 to 100

 

40 VDC AT

 

SAW-DC+

}

 

Output Range

VRMS

 

10 AMPS

 

SAW-DC-

 

200-1000 Average Amps

 

 

115 VAC AT

 

SAW-AC

 

 

 

 

 

 

10 AMPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED INPUT WIRE AND FUSE SIZES1

 

3 PHASE INPUT

 

TYPE 90°C

 

COPPER GROUNDING

TIME-DELAY FUSE

VOLTAGE 50/60Hz

 

COPPER WIRE3 IN

 

CONDUCTOR

OR BREAKER2

 

 

 

 

CONDUIT

 

 

 

 

 

 

 

 

 

 

 

AWG (mm2)

 

 

 

AWG (mm2)

 

AMPS

 

380

 

 

3(25)

 

 

 

8 (10)

 

100

 

400

 

 

3(25)

 

 

 

8 (10)

 

90

 

460

 

 

4(25)

 

 

 

8 (10)

 

90

 

500

 

 

4(25)

 

 

 

8 (10)

 

80

 

575

 

 

6(16)

 

 

 

10 (6)

 

70

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

MODEL

 

CONFORMITY MARK

 

HEIGHT

WIDTH

DEPTH

 

WEIGHT

K2344-1

 

 

 

CSA C/UL

 

43.5 in

19.2 in

33 in

 

600 lbs.

 

 

 

 

1105 mm

488 mm

838 mm

 

272 kg.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K2344-2

*

 

 

EN 60974-1

 

43.5 in

19.2 in

33 in

 

650 lbs.

 

 

CSA C/UL

 

1105 mm

488 mm

838 mm

 

296 kg.

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE RANGES

 

 

 

OPERATING TEMPERATURE RANGE

 

STORAGE TEMPERATURE RANGE

 

 

32°F to 104°F(0°C to 40°C)

 

-40°F to 185°F(-40°C to 85°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

Insulation Class: Class F(155°C)

1Wire and Fuse Sizes based upon the U.S. National Electric Code and maximum output for 40°C (104°) ambient.

2Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers that have a delay in tripping action that decreases as the magnitude of current increases.

3Fail to use proper type of copper wire will cause fire hazards.

*An external filter will be required to meet CE and C-Tick conducted emission requirements. It will meet CE and C-Tick requirements with the use of an optional external filter. (K2444-1 CE and C-Tick Filter Kit)

WELDING PROCESSES

Process

Electrode Diameter Range Output Range (Amperes

Wire Feed Speed Range

SAW

5/64 – 7/32" (2 – 5.6 mm)

200 - 1000

21 - 300 ipm (.53 – 7.62 m/minute)

POWER WAVE® AC/DC 1000

Page 11
Image 11
Lincoln Electric 11124, 11226 manual Specifications