E-3

 

 

TROUBLESHOOTING

 

E-3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

 

POSSIBLE

 

RECOMMENDED

 

 

 

(SYMPTOMS)

 

 

CAUSE

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Machine won’t weld, can’t get any

 

 

1. Input voltage is too low or too

 

 

1. Make certain that input voltage is

 

 

output. (CR1 will not pull in.)

 

 

high.

 

 

proper, according to the Rating

 

 

 

 

 

 

 

 

 

 

Plate located on the rear of the

 

 

 

This problem will normally be

 

 

 

 

 

machine.

 

 

 

 

accompanied by an error code.

 

 

 

 

 

 

 

 

 

 

Error codes are displayed as a

 

 

2. Thermal Error.

 

 

2. See "Thermal LED is ON" sec-

 

 

 

series of red and green flashes by

 

 

 

 

 

tion.

 

 

 

 

the status light(s). See "Status

 

 

 

 

 

 

 

 

 

 

Light" section of this document for

 

 

3. Primary current limit has been

 

 

3. Possible short in output circuit.

 

 

 

additional information.

 

 

exceeded. (CR1 drops out when

 

 

Turn machine off.

Remove all

 

 

 

 

 

 

 

output is initiated).

 

 

loads from the output of the

 

 

 

 

 

 

 

 

 

 

machine. Turn back on, and acti-

 

 

 

 

 

 

 

 

 

 

vate output. If condition persists,

 

 

 

 

 

 

 

 

 

 

turn power off, and contact an

 

 

 

 

 

 

 

 

 

 

authorized Lincoln Electric Field

 

 

 

 

 

 

 

 

 

 

Service facility.

 

 

 

 

 

 

 

 

4. Inverter Fault - switch pc board,

 

 

4. Contact your local authorized

 

 

 

 

 

 

 

contactor problem, etc.

 

 

Lincoln Electric Field Service

 

 

 

 

 

 

 

 

 

 

facility for technical assistance.

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermal LED is on.

 

 

1. Improper fan operation.

 

 

1. Check for proper fan operation.

 

 

 

 

 

 

 

 

 

 

(Fans should run whenever out-

 

 

 

 

 

 

 

 

 

 

put power is on.)

Check for

 

 

 

 

 

 

 

 

 

 

material blocking

intake or

 

 

 

 

 

 

 

 

 

 

exhaust louvers, or for excessive

 

 

 

 

 

 

 

 

 

 

dirt clogging cooing channels in

 

 

 

 

 

 

 

 

 

 

machine.

 

 

 

 

 

 

 

 

2. Switch Board or AC Output

 

 

2. After machine has cooled,

 

 

 

 

 

 

 

Chopper board thermostat.

 

 

reduce load, duty cycle, or both.

 

 

 

 

 

 

 

 

 

 

Check for material blocking

 

 

 

 

 

 

 

 

 

 

intake or exhaust louvers.

 

 

 

 

 

 

 

3. DC Bus PC board thermostat

 

 

3. Check for excessive load on

 

 

 

 

 

 

 

 

 

 

40VDC supply.

 

 

 

 

 

 

 

 

4. Open thermostat circuit.

 

 

4. Check for broken wires, open

 

 

 

 

 

 

 

 

 

 

connections or faulty ther-

 

 

 

 

 

 

 

 

 

 

mostats DC Bus, Switch, and AC

 

 

 

 

 

 

 

 

 

 

Chopper PC Board heat sinks.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

POWER WAVE® AC/DC 1000

Page 54
Image 54
Lincoln Electric 11226, 11124 manual Recommended Symptoms